Permit Information - Permit 23060976

Loading permit details...

Permit Information
Permit Number 23060976 Property ID 74434333480010000
Permit Desc COM-MISC Balance Due $0.00
Property Address 2751 S DIXIE HWY Status Open

Permit Plan Reviews Inspections Fees Contractors All
Permit
Permit Information
Application Date 2023-06-20 Operator amcgrego
Issued Date   Operator  
Master Number   Project Number  
C.O. Number   Operator  
C.O. Issued  
C-404 Type   Usage Class PRIVATE
Applied Value 6000 Units 0
Calculated Value 0 Contractor ID FL00843
Property On Permit
Property ID 74434333480010000    
Building Ext.  
Address 2751 S DIXIE HWY
City WEST PALM BEACH
State FL
Zip Code 33405
Owner On Permit
Name TRICERA PBP PROPERTY OWNER LLC
Address 80 SW 8TH ST # 2100
City MIAMI Type  
State FL Zip Code 33130 3047
Miscellaneous Information / Notes
OUTDOOR AWNING 2751 S DIXIE HWY PINK STEAK
RESTAURANT
 
6/29/23 FAILED FIRE CLF
 
THIS PLAN WAS REVIEWED AND FAILED BY CAITLIN L
FRANCIS, FIRE INVESTIGATOR, WITH THE FOLLOWING
COMMENTS:
 
1) THERE ARE NO SPECIFICATIONS OF THE MATERIAL OR
STRUCTURE OF THE CANOPY SUBMIT WITH THE SITE PLAN,
AND THESE MUST MEET THE FOLLOWING CODES FROM NFPA
13 CHAPTER 8:
 
8.15.7* EXTERIOR PROJECTIONS.
8.15.7.1 UNLESS THE REQUIREMENTS OF 8.15.7.2,
8.15.7.3, OR
8.15.7.4 ARE MET, SPRINKLERS SHALL BE INSTALLED
UNDER EXTERIOR
PROJECTIONS EXCEEDING 4 FT (1.2 M) IN WIDTH.
8.15.7.2* SPRINKLERS SHALL BE PERMITTED TO BE
OMITTED WHERE
THE EXTERIOR PROJECTIONS ARE CONSTRUCTED WITH
MATERIALS THAT
ARE NONCOMBUSTIBLE, LIMITED-COMBUSTIBLE, OR FIRE
RETARDANT???
TREATED WOOD AS DEFINED IN NFPA 703.
8.15.7.3 SPRINKLERS SHALL BE PERMITTED TO BE
OMITTED FROM BELOW
THE EXTERIOR PROJECTIONS OF COMBUSTIBLE
CONSTRUCTION, PROVIDED
THE EXPOSED FINISH MATERIAL ON THE EXTERIOR
PROJECTIONS ARE NONCOMBUSTIBLE,
LIMITED-COMBUSTIBLE, OR FIRE RETARDANT???TREATED
WOOD AS DEFINED IN NFPA 703, AND THE EXTERIOR
PROJECTIONS CONTAIN
ONLY SPRINKLERED CONCEALED SPACES OR ANY OF THE
FOLLOWING
UNSPRINKLERED COMBUSTIBLE CONCEALED SPACES:
(1) COMBUSTIBLE CONCEALED SPACES FILLED ENTIRELY
WITH NONCOMBUSTIBLE
INSULATION
(2) LIGHT OR ORDINARY HAZARD OCCUPANCIES WHERE
NONCOMBUSTIBLE
OR LIMITED-COMBUSTIBLE CEILINGS ARE DIRECTLY
ATTACHED
TO THE BOTTOM OF SOLID WOOD JOISTS SO AS TO CREATE
ENCLOSED
JOIST SPACES 160 FT3 (4.5 M3) OR LESS IN VOLUME,
INCLUDING
SPACE BELOW INSULATION THAT IS LAID DIRECTLY ON
TOP OR WITHIN
THE CEILING JOISTS IN AN OTHERWISE SPRINKLERED
ATTIC [SEE
11.2.3.1.4(4)(D)]
(3) CONCEALED SPACES OVER ISOLATED SMALL EXTERIOR
PROJECTIONS
NOT EXCEEDING 55 FT2 (5.1 M2) IN AREA
8.15.7.4 SPRINKLERS SHALL BE PERMITTED TO BE
OMITTED FROM
EXTERIOR EXIT CORRIDORS WHEN THE EXTERIOR WALLS OF
THE CORRIDOR
ARE AT LEAST 50 PERCENT OPEN AND WHEN THE CORRIDOR
IS ENTIRELY
OF NONCOMBUSTIBLE CONSTRUCTION.
8.15.7.5* SPRINKLERS SHALL BE INSTALLED UNDER
EXTERIOR PROJECTIONS
GREATER THAN 2 FT (0.6 M) WIDE OVER AREAS WHERE
COMBUSTIBLES
ARE STORED.
 
CAITLIN L FRANCIS
FIRE INVESTIGATOR
WEST PALM BEACH FIRE RESCUE
561.804.4728
[email protected]
 
 
 
6/21/23 FEES PAID, PLANS UPLOADED, INCOMING
COMPLETE. AM
6/20/23 APPLICANT INVITED TO UPLOAD PLANS AND PAY
FEES. AM