Date Text
2022-09-06 15:29:299/6/22 ? FAILED
  
  
 PLEASE NOTE THE FOLLOWING PROCESS COMMENTS WHEN
 RESUBMITTING:
 A. WRITTEN RESPONSES TO COMMENTS MADE BY ALL
 DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION.
 B. PROVIDE AN ELECTRONIC COPY OF ALL PLANS AND REQUIRED
 MATERIALS AND 2 SETS OF FOLDED PHYSICAL PLANS, ALONG
 WITH ONE (1) REDUCED COPY (11 IN X 17 IN).
 C. PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO
 ADDITIONAL COMMENTS.
 D. IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE
 ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE
 CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL
 REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION.
 E. PLEASE NOTE THAT YOU ARE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. A RESUBMITTAL FEE OF
 20% OF THE ORIGINAL APPLICATION FEE WILL BE ASSESSED
 AFTER THE FIRST RESUBMITTAL.
  
 REQUIRED MATERIALS MUST BE PROVIDED:
 F. PLEASE PROVIDE CONFIRMATION LETTERS FROM PUBLIC
 UTILITIES (AT&T TELECOMMUNICATION, FLORIDA PUBLIC
 UTILITIES, AND COMCAST CABLE COMMUNICATIONS) CONFIRMING
 THAT THE PROPOSED PROJECT DOES NOT ENCROACH INTO THEIR
 EASEMENTS OR OTHERWISE INTERFERE WITH THE PROVISIONS OF
 THEIR SERVICES.
 G. PLEASE PROVIDE EVIDENCE OF THE UNIFIED CONTROL OF
 THE ENTIRE AREA.
 H. PLEASE PROVIDE THE AGREEMENTS, PROVISIONS OR
 COVENANTS WHICH GOVERN THE USE, MAINTENANCE AND
 CONTINUED PROTECTION OF THE PD AND ANY OF ITS COMMON
 AREAS OR FACILITIES.
 I. PLEASE PROVIDE REVISED PLANS ADDRESSING THE REVIEW
 COMMENTS BELOW.
 J. PLEASE PROVIDE/INDICATE/DEMONSTRATE CONSISTENT
 INFORMATION ON ALL THE DIFFERENT PLANS AND REQUIRED
 MATERIALS WITHIN THE APPLICATION PACKET RESUBMITTAL.
 K. PLEASE PROVIDE COMPLETED PUBLIC NOTICE MAILER
 AFFIDAVITS WHEN MAILERS HAVE BEEN SENT OUT.
 L. PLEASE PROVIDE COMPLETED SIGN POSTING AFFIDAVITS
 WHEN SIGNS HAVE BEEN PUT UP.
  
 REVIEW COMMENTS MUST BE ADDRESSED:
 1. IN ACCORDANCE WITH THE CITY?S ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDR) SUBSECTION
 94-207(B)(9)(A)(1), PLEASE IDENTIFY/INDICATE THE NAME
 OF THE DEVELOPER ON THE ?COVER? SHEET NUMBER A-0 AND/OR
 ?SITE PLAN? SHEET NUMBER A-1.
 2. THE PROPOSAL DEMONSTRATED IS NOT IN COMPLIANCE WITH
 THE (VISIBILITY TRIANGLE AT INTERSECTIONS REQUIREMENT)
 ZLDR SUBSECTION 94-207(B)(6), THEREFORE, PLEASE REVISE
 THE DIFFERENT PLANS, ELEVATIONS, AND SECTION,
 ACCORDINGLY.
 3. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE EXISTING
 AND PROPOSED EASEMENTS ON THE DIFFERENT PLANS.
 4. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE EXISTING
 AND PROPOSED FIRE HYDRANTS (OR OPERATIONAL EQUIVALENTS)
 WITHIN 250 FEET OF THE PROPOSED STRUCTURE(S) ON THE
 ?SITE PLAN? SHEET NUMBER A-1.
 5. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION OF
 ANY SPECIAL UTILITY STRUCTURES SUCH AS VALVES, METERS,
 BACKFLOW CONNECTIONS, PUMP STATIONS, TRANSFORMERS, AND
 ALL ABOVE GROUND APPURTENANCES ON THE ?SITE PLAN? SHEET
 NUMBER A-1.
 6. THE PROPOSED LOADING SPACES ARE NOT IN COMPLIANCE
 WITH THE MINIMUM LOADING SPACE DIMENSIONAL REQUIREMENTS
 OF THE ZLDR SUBSECTION 94-485(P), THEREFORE PLEASE
 REVISE THE DIFFERENT PLANS, ACCORDINGLY.
 7. PLEASE FURTHER EXPLAIN/CLARIFY/CONFIRM WHETHER THE
 PROPOSED LOADING SPACES ARE FOR THE PROPOSED
 SELF-STORAGE USE OR FOR ALL THE PROPOSED USES.
 8. IN ACCORDANCE WITH THE ZLDR SUBSECTION 94-485(Q),
 PLEASE IDENTIFY/INDICATE THE REQUIRED AND PROPOSED
 NUMBER OF BICYCLE PARKING SPACES IN THE ?PARKING? TABLE
 ON THE ?SITE PLAN? SHEET NUMBER A-1.
 9. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE EXISTING
 BIKE LANE (TO REMAIN) ALONG LA KIRKSEY/15TH STREET ON
 THE ?BOUNDARY SURVEY? AND ?SITE PLAN? SHEET NUMBER A-1.
 10. IN ACCORDANCE WITH THE ZLDR SUBSECTION
 94-207(B)(9)(A)(7), PLEASE
 IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION OF PROPOSED
 MASS TRANSIT FACILITIES ON THE ?SITE PLAN? SHEET NUMBER
 A-1.
 11. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE CURB
 CUTS/CONCRETE DRIVE ACCESSES REMOVED ALONG DIXIE
 HIGHWAY ON THE DIFFERENT PLANS, ACCORDINGLY, SIMILAR TO
 THE INFORMATION DISPLAYED ON THE ?SITE PLAN? SHEET
 NUMBER C-02, ?DEMOLITION PLAN? SHEET NUMBER C-03, AND
 ?PAVING, GRADING, AND DRAINAGE PLANS? SHEET NUMBER
 C-04.
 12. PLEASE DEMONSTRATE HOW THE CITY?S SANITATION
 SERVICE TRUCKS WILL ACCESS/COLLECT THE TRASH FROM THE
 PROPOSED TRASH AREA TO THE SOUTH ON THE ?AUTOTURN
 EXHIBIT? SHEET NUMBER C-07.
 13. IN ACCORDANCE WITH THE ZLDR SUBSECTION 94-443,
 PLEASE REVISE THE DIFFERENT PLANS AND ELEVATIONS,
 ACCORDINGLY, TO IDENTIFY/INDICATE/DEMONSTRATE THE
 REQUIRED PROTECTIVE SCREEN WALL ALONG THE WEST PROPERTY
 LINE ADJACENT TO THE RESIDENTIAL PROPERTY/RESIDENTIAL
 ZONING DISTRICT.
 14. IT HAS BEEN IDENTIFIED THAT THERE ARE
 INCONSISTENCIES BETWEEN THE PLANS AND ELEVATIONS
 REGARDING THE PROPOSED FIVE-FOOT-HIGH SECURITY/ALUMINUM
 FENCE, THEREFORE PLEASE REVISE, ACCORDINGLY.
 15. PLEASE PROVIDE AN
 ILLUMINATION/LIGHTING/PHOTOMETRICS PLAN DEMONSTRATING
 COMPLIANCE WITH THE ZLDR SUBSECTION 94-207(D)(8).
 16. IN ACCORDANCE WITH THE ZLDR SUBSECTION 94-409,
 PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE PROPOSED
 BUILDING FA?ADE SIZE, PERCENT SIGNAGE PERMITTED, AND
 PERMITTED SIGN SIZE FOR THE PROPOSED WALL MOUNTED SIGNS
 ON THE ?COLOR ELEVATIONS? SHEET NUMBERS A-3 TO A-4.
 17. THE PROPOSED ?WEST ELEVATION? WALL MOUNTED SIGN IS
 NOT IN COMPLIANCE WITH THE ZLDR SUBSECTION
 94-402(B)(2)(7), THEREFORE PLEASE REVISE THE ?COLOR
 ELEVATION? SHEET NUMBER A-4, ACCORDINGLY.
 18. PLEASE PROVIDE THE STANDARD CITY DETAILS OF
 VEHICLE/BICYCLE PARKING (STANDARD, COMPACT, ADA),
 LOADING, ADA RAMPS, DRIVEWAYS, DUMPSTERS AND SIGNS.
 19. PLEASE UPDATE THE ?SITE DATA? ON THE ?SITE PLAN?
 SHEET NUMBER A-1 TO IDENTIFY/INDICATE THE CORRESPONDING
 DATA FOR THE ?ALLOWED? INFORMATION WITHIN THE EXISTING
 MF14 AND GC ZONING DISTRICTS.
 20. PLEASE UPDATE THE ?SITE DATA? ON THE ?SITE PLAN?
 SHEET NUMBER A-1 TO IDENTIFY/INDICATE THE MAXIMUM AND
 PROPOSED LOT COVERAGE BY BUILDINGS AND IMPERMEABLE
 SURFACE ACCORDING TO THE ZLDR SECTIONS 94-241 AND
 94-243.
 21. PLEASE CORRECT THE ?SITE DATA? ON THE ?SITE PLAN?
 SHEET NUMBER A-1 TO IDENTIFY/INDICATE THE MAXIMUM
 BUILDING HEIGHTS (?ALLOWED?) INFORMATION ACCORDING TO
 THE ZLDR SUBSECTIONS 94-241 AND 94-243 FOR THE EXISTING
 MF14 AND GC ZONING DISTRICTS AND ADD THE PROPOSED
 HEIGHT ?TO THE TOP OF THE PARAPET? INFORMATION TO
 REFLECT THE SAME INFORMATION DEMONSTRATED IN THE
 ELEVATIONS.
 22. PLEASE CORRECT THE ?SITE DATA? ON THE ?SITE PLAN?
 SHEET NUMBER A-1 TO IDENTIFY/INDICATE THE PROPOSED
 ?FRONT (EAST SIDE)? SETBACK TO REFLECT THE SAME
 INFORMATION DEMONSTRATED IN THE GRAPHIC/PLAN.
 23. PLEASE CORRECT THE ?PARKING? TABLE ON THE ?SITE
 PLAN? SHEET NUMBER A-1 TO IDENTIFY/INDICATE THE
 PROPOSED NUMBER OF PARKING SPACES IN WHOLE NUMBERS
 ACCORDING TO THE ZLDR SUBSECTION 94-485(H); TO
 IDENTIFY/INDICATE CORRECT INFORMATION FOR THE MINIMUM
 NUMBER OF REQUIRED ?STORAGE OFFICE? PARKING SPACES
 ACCORDING TO THE ZLDR SECTION 94-486; TO
 IDENTIFY/INDICATE THE CORRECT INFORMATION FOR THE TOTAL
 MINIMUM NUMBER OF REQUIRED PARKING SPACES; AND TO
 IDENTIFY/INDICATE THE MINIMUM REQUIRED NUMBER OF ?H.C.
 (INCLUSIVE)? PARKING SPACES ACCORDING TO THE ZLDR
 SUBSECTION 94-485(O).
 24. PLEASE CORRECT THE ?LOADING? TABLE ON THE ?SITE
 PLAN? SHEET NUMBER A-1 TO INDICATE THE MINIMUM LOADING
 SPACE DIMENSIONAL REQUIREMENTS ACCORDING TO THE ZLDR
 SUBSECTION 94-485(P).
 25. IT HAS BEEN IDENTIFIED THAT THERE ARE
 INCONSISTENCIES BETWEEN THE ?SITEPLAN? SHEET NUMBER
 A-1, ?SITE PLAN? SHEET NUMBER C-02, AND ?LANDSCAPE
 PLAN? SHEET NUMBER L-2.0 REGARDING THE SITE DATA
 INFORMATION, THEREFORE PLEASE REVISE, ACCORDINGLY.
  
  