2022-09-07 14:34:13 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, |
| COMMENTS: |
| |
| 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE |
| SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH |
| FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE |
| ADDRESSED FOR THE BUILDING PERMIT APPLICATION. |
| |
| 2. DEMOLITION OF THE EXISTING BUILDING. AN ASBESTOS |
| SURVEY SHALL BE PERFORMED AND AN ASBESTOS ABATEMENT |
| REPORT SUBMITTED TO THE HEALTH DEPARTMENT PALM BEACH |
| COUNTY OFFICE. CONTACT ALEX ORTEGA AT (561) 837-5963, |
| OR BY EMAIL: [email protected] |
| |
| 3. UNITY OF TITLE. FOR ANY BUILDING CROSSING A PROPERTY |
| LINE, EITHER A RECORDED UNITY OF TITLE, OR SOME OTHER |
| APPROVED LEGAL INSTRUMENT, SHALL BE INCLUDED WITH THE |
| PERMIT APPLICATION, OR THE BUILDING MUST HAVE A FIRE |
| WALL ALONG THE PROPERTY LINE, PER SECTION 202 OF |
| FLORIDA BUILDING CODE, BUILDING, FIRE SEPARATION |
| DISTANCE. |
| |
| 4. VAN ACCESSIBLE PARKING SPACES. THE PLANS DO NOT SHOW |
| A VAN ACCESSIBLE PARKING SPACE. PER SECTION 208.2.4 OF |
| FLORIDA ACCESSIBILITY CODE, ONE IN EVERY SIX REQUIRED |
| ACCESSIBLE SPACES (AT LEAST ONE) IN A PARKING |
| STRUCTURE, SHALL BE ?VAN ACCESSIBLE? AND DESIGNED IN |
| ACCORDANCE WITH SECTION OF 502 OF FLORIDA ACCESSIBILITY |
| CODE (VERTICAL CLEARANCE NOT LESS THAN 98 INCHES AT |
| SPACE AND VEHICULAR ACCESS ROUTE) |
| |
| 5. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, |
| THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR |
| THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, |
| AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE |
| FLORIDA BUILDING CODE. |
| |
| 6. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND |
| OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT, |
| COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF |
| OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF |
| CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE |
| VERIFIED. \ |
| |
| 7. ENCLOSED PARKING GARAGES. IF THE PARKING GARAGE DOES |
| NOT HAVE WALL OPENINGS, OR SUFFICIENT WALL OPENINGS TO |
| MEET THE DEFINITION OF AN OPEN PARKING GARAGE, IT WILL |
| BE CONSIDERED AN ENCLOSED PARKING GARAGE AND MUST HAVE |
| EXHAUST SYSTEMS. THE EXHAUST SYSTEMS SHALL BE DESIGNED |
| TO MINIMIZE NOISE LEVELS USING INLINE FAN SILENCERS OR |
| OTHER APPROVED METHODS. |
| |
| 8. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS |
| AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE |
| WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED |
| FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, |
| FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, |
| GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, |
| SITE IRRIGATION, ETC. |
| |
| 9. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND |
| CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF |
| CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL |
| NEIGHBORING PROPERTIES. |
| |
| 10. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER |
| AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY, |
| INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE |
| CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF |
| NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION |
| THAT MAY AFFECT THE USE OF THEIR PROPERTY. |
| |
| 11. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT |
| WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL |
| HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION |
| OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING, |
| CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT |
| (561) 805 6659, OR BY EMAIL: [email protected] |
| |
| |
| ROBERT BROWN |
| BUILDING OFFICIAL |
| TEL: 561 805 6652 |
| EMAIL: [email protected] |
| |
|