2021-03-10 20:40:55DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR THE BUILDING PERMIT APPLICATION.
  
 2 UPDATED: FLOOD ZONE. ACCORDING TO THE ADOPTED FLOOD
 INSURANCE RATE MAPS (FIRMS), THE PROPOSED BUILDING IS
 IN FLOOD ZONE A, BUT THE BASE FLOOD ELEVATION IS
 UNDETERMINED. MORE RESEARCH WILL BE REQUIRED TO
 ESTABLISH THE BASE FLOOR ELEVATION PRIOR TO PERMITTING.
 UPDATE: THE CITY STORMWATER ENGINEER HAS POINTED OUT
 THAT THE SOUTH FLRIDA WATER MANAGEMENT DISTRICT (SFWMD)
 CONTOUR MAP SHOWS THE SITE BOUNDED BY THE 13.0 FT NAVD
 88 CONTOUR ELEVATION. THE FIRST FLOOR OF THE BUILDING
 AND ALL ASSOCIATED MECHANICAL EQUIPMENT (CHILLERS,
 GENERATORS ETC.) SHALL BE 24 INCHES (FREEBOARD) ABOVE
 THE BASE FLOOD ELEVATION.
  
 3. ACCESSIBLE ROUTE. SITE PLAN, SHEET SP.1, DOES NOT
 SHOW A WHEELCHAIR ACCESSIBLE ROUTE FROM THE SIDEWALK TO
 THE BUILDING ENTRANCE. WHEN SUBMITTED FOR PERMIT, THE
 PLANS SHALL SHOW AT LEAST ONE ACCESSIBLE ROUTE,
 COMPLYING WITH SECTIONS 206.2 AND 402.2 OF FLORIDA
 ACCESSIBILITY CODE, FROM THE PUBLIC RIGHT-OF-WAY TO ALL
 ACCESSIBLE BUILDING OR FACILITY ENTRANCES.
  
 4. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT,
 THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR
 THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT,
 AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE
 FLORIDA BUILDING CODE.
  
 5. GREASE INTERCEPTOR. A GREASE INTERCEPTOR WILL BE
 REQUIRED. FOR INFORMATION ON THE REQUIRED TYPE, SIZE
 AND LOCATION, PLEASE CONTACT TIM LARGE, CHIEF PLUMBING
 INSPECTOR, DEVELOPMENT SERVICES DEPARTMENT, AT (561)
 805-6692, OR BY EMAIL: [email protected]
  
 6. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS
 AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE
 WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED
 FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS,
 FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS,
 GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE,
 SITE IRRIGATION, ETC.
  
 7. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER
 AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY,
 INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE
 CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF
 NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION
 THAT MAY AFFECT THE USE OF THEIR PROPERTY.
  
  
 ROBERT BROWN
 BUILDING OFFICIAL