Date |
Text |
2019-05-08 12:04:30 | 1. TWO DIFFERENT SURVEYS WERE SUBMITTED FOR THE |
| PROJECT. PLEASE UPDATE SURVEY TO INDICATE CURRENT |
| PROPERTY OWNERS. SURVEY SHOWS PARCEL 1 AND 2 IS OWNED |
| BY RUSSO DS&. AND PARCEL 4 AND 5 IS SHOWN AS OWNED BY |
| GARDENIA LLC. |
| 2. FOR ALL OWNERS OTHER THAN BRIGHT BLUE LLC PLEASE |
| PROVIDE OWNER?S CONSENT FORM. |
| 3. PLEASE INDICATE THE WIDTH OF THE EXISTING SIDEWALKS |
| IN THE SURVEY. |
| 4. SITE AREA REFLECTED ON MSA SURVEY (48,614SF) IS |
| DIFFERENT THAN INDICATED IN SHEET A-0.7. PLEASE CLARIFY |
| WHAT IS THE CORRECT AREA AND ADJUST DRAWINGS |
| ACCORDINGLY. WALLACE SURVEY DOES NOT CONTAIN TOTAL LAND |
| AREA INFORMATION. |
| 5. PARKING USES ALONG GARDENIA AVENUE, ABOVE THE 3RD |
| STORY SHALL BE SET-BACK A MINIMUM OF 27? FROM THE BACK |
| OF CURB. |
| 6. THE PROPOSED BUILDING MASSING SHALL BE RECONSIDERED. |
| THE 24 STORY BUILDING RELATIONSHIP WITH THE SMALL |
| DOUBLE HEIGHT RESIDENTIAL LOBBY AT THE CORNER OF DIXIE |
| AND GARDENIA IS NOT APPROPRIATE. |
| 7. THE BUILDING AREA ABOVE THE RESIDENTIAL LOBBY IS NOT |
| IN COMPLIANCE WITH THE MAXIMUM 35 FEET SETBACK FOR |
| FLOOR 3RD TO 7TH. |
| 8. ACTIVE USES ALONG DIXIE HWAY ARE REQUIRED ALONG 65% |
| OF GROUND FLOOR FRONTAGE. BUILDABLE LOT FRONTAGE = |
| 130.8, REQUIRED ACTIVE USE=85.02SF. |
| 9. PROJECT DOES NOT COMPLY WITH ACTIVE USE REQUIREMENTS |
| ALONG DIXIE HWAY ABOVE THE SECOND STORY (RESIDENTIAL |
| LOBBY COUNTED AS TWO STORIES). 60% ACTIVE USES REQUIRED |
| ALONG DIXIE HWAY FRONTAGE. |
| 10. PHOTOGRAPHIC POLYVINYL COATED MESH IS NOT IN |
| COMPLIANCE WITH THE ARCHITECTURAL TREATMENT REQUIRED |
| FOR NON-ACTIVE USES. |
| 11. ALL NON-ACTIVE USE FACADES ARE REQUIRED TO PROVIDE |
| ARCHITECTURAL TREATMENTS. PLEASE REVISE ALL GARAGE |
| ELEVATION TO PROVIDE ARCHITECTURAL TREATMENT. |
| 12. RESIDENTIAL LOBBY DOOR ON DIXIE HWAY SHALL BE |
| RECESSED TO AVOID ENCROACHMENT INTO PEDESTRIAN PATH. |
| 13. GARAGE AND STAIRS ELEVATION AT THE NW CORNER DOES |
| NOT COMPLY WITH ARCHITECTURAL TREATMENT REQUIREMENTS. |
| 14. PLEASE PROVIDE AUTOTURN TO CONFIRM TRUCKS CAN |
| ACCESS THE PROPOSED LOADING AREA. |
| 15. PLEAS EDISCUSS WITH PUBLIC WORKS THE GARBAGE PICK |
| UP OPERATION. |
| 16. PLEASE EXPLAIN THE OPERATION OF THE EXISTING ALLEY. |
| 17. PARKING STALLS SHALL BE INCREASED BY ONE FOOT WHEN |
| ADJACENT TO A WALL OR OTHER BUILDING OBSTRUCTION (SEC |
| 94-111(C)). |
| 18. SETBACK DIAGRAM PROVIDED IN SHEET A-0.11 SHALL |
| INCLUDE INFORMATION MEASURED FROM THE BACK OF CURB. THE |
| PROPERTY LINE SHALL BE INDICATED. |
| 19. PLEASE PROVIDE GRAPHIC INFORMATION TO CONFIRM |
| COMPLIANCE WITH TRANSPARENCY REQUIREMENTS AT THE GROUND |
| LEVEL. |
| 20. SITE PLAN SHALL INCLUDE INFORMATION INDICATING THE |
| LOCATIONS OF THE EXISTING BUILDINGS ON THE NORTH SIDE |
| OF THE ALLEY. |
| 21. PLEASE PROVIDE COLORED ELEVATIONS WITH CALL OUT |
| MATERIALS AND IMAGES WITH MATERIALS REFERENCES. |
| 22. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE |
| WITH PLANAR BREAK REQUIREMENTS. |
| 23. PLEASE PROVIDE A SUMMARY TABLE INCLUDING, LOT AREA, |
| FAR PERMITTED BY RIGHT, ADDITIONAL FAR WITH INCENTIVES, |
| TOTAL GROSS BUILDING AREA PROPOSED PER FLOOR AND TOTAL. |
| IN THE FLOOR PLANS ASSOCIATED WITH THE GROSS BUILDING |
| AREA INFORMATION, PLEASE LABEL THE SPACES TO CLEARLY |
| IDENTIFY THOSE AREAS EXCLUDED FROM THE GBA NUMBERS. |
| PLEASE USE THE GBA DEFINITION IN SECTION 94-109. |
| 24. PLEASE PROVIDE A BREAKDOWN OF HOTEL ROOMS AND |
| RESIDENTIAL UNITS TO CONFIRM COMPLIANCE WITH MINIMUM |
| UNIT SIZE, AND AVERAGE UNIT SIZE REQUIRED BY CODE SEC |
| 94-109 FULL SERVICE HOTEL DEFINITION AND DWELLING UNIT |
| DEFINITION. |
| 25. PLEASE PROVIDE GRAPHICS INDICATING THE AREA |
| CALCULATED TO COMPLY WITH THE PUBLIC OPEN SPACE AND THE |
| PRIVATE OPEN SPACE REQUIREMENTS AND CONFIRM COMPLIANCE |
| WITH EACH OF THE REQUIREMENTS FOR EACH OPEN SPACE TYPE. |
| 26. PUBLIC OPEN SPACE AT GROUND LEVEL DOES NOT SEEM TO |
| COMPLY WITH MINIMUM PROPORTIONS REQUIRED BY THE CODE. |
| 27. PLEASE PROVIDE PHOTOMETRICS TO CONFIRM COMPLIANCE |
| WITH ILLUMINATION ON THE PUBLIC RIGHT OF WAY. STANDARD |
| DECORATIVE STREET LIGHT FIXTURES AND POLES SHALL BE |
| PROVIDED ALONG THE STREET FRONTAGES TO MEET MINIMUM 0.6 |
| FOOTCANDLES AT ONE FOOT ABOVE THE SIDEWALK LEVEL NEXT |
| TO THE CURB. FIXTURE AND POLE SHALL MEET APPROVED CITY |
| STANDARD. |
| 28. EXISTING UNDERGROUND ELECTRIC CONFLICTS WITH |
| PROPOSED STREET TREES ALONG GARDENIA. PLEASE DETERMINE |
| THE POSSIBILITY FOR RELOCATION. |
| 29. SIDEWALK ELEVATION SHALL BE MAINTAINED ACROSS THE |
| PARKING GARAGE DRIVEWAY. PLEASE INCLUDE A NOTE AND |
| SECTION WITHIN THE CIVIL DRAWINGS TO ENSURE COMPLIANCE. |
| 30. PLEASE VERIFY RENDERINGS ACCURATELY REFLECT THE |
| BUILDING DESIGN, PROPOSED MATERIALS AND LANDSCAPE. |
| RENDERINGS WILL BE PART OF THE APPROVAL SET. |
| 31. QUADRILLE BLVD IS AN FDOT RIGHT OF WAY. PLEASE |
| CONFIRM PROPOSED LANDSCAPE COMPLIES WITH FDOT |
| STANDARDS. |
| 32. PLEASE INDICATE THE LOCATION OF SECURED BIKE |
| PARKIGN FOR RESIDENTIAL TENANTS(1/15 REQUIRED PARKIGN |
| SPACES), AND THE LOCATION OF REQUIRED PULBIC BIKE |
| PARKIGN ALONG THE STREET FRONTAGES 1/100 FEET OF STREET |
| FRONTAGE). |
| |
| PLEASE RE-SUBMIT DRAWINGS ADDRESSING THE COMMENTS FROM |
| ALL THE DISCIPLINES, AND INCLUDE A RESPONSE LETTER WITH |
| ANSWERS TO EACH COMMENT. |
| PROJECT WOULD BE REQUIRED TO OBTAIN DAC APPROVAL FOR |
| SPECIAL REVIEW, AND THE TRANSFER OF DEVELOPMENT RIGHTS. |
| FOR ADDTIONAL INFORMATION PLEASE CONTACT ANA MARIA |
| APONTE AT 561-822-1439. |
| |
| |
|
Print |