2019-05-06 20:32:18DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR THE BUILDING PERMIT APPLICATION.
  
 2. DEMOLITION OF THE EXISTING BUILDINGS. AN ASBESTOS
 SURVEY SHALL BE PERFORMED AND AN ASBESTOS ABATEMENT
 REPORT SUBMITTED TO THE HEALTH DEPARTMENT PALM BEACH
 COUNTY OFFICE. CONTACT ALEX ORTEGA AT (561) 837-5963,
 OR BY EMAIL: [email protected]
  
 3. UNITY OF TITLE. FOR ANY BUILDING CROSSING A PROPERTY
 LINE, EITHER A RECORDED UNITY OF TITLE, OR SOME OTHER
 APPROVED LEGAL INSTRUMENT, SHALL BE INCLUDED WITH THE
 PERMIT APPLICATION, OR THE BUILDING MUST HAVE A FIRE
 WALL ALONG THE PROPERTY LINE, PER SECTION 202 OF
 FLORIDA BUILDING CODE, BUILDING, FIRE SEPARATION
 DISTANCE.
  
 4. EXIT STAIRS NOT DISCHARGING TO THE EXTERIOR OF THE
 BUILDING. GROUND FLOOR PLAN, SHEET A-1.1, SHOWS STAIR
 #1, #3 AND #4 ALL DISCHARGING INTERNAL TO THE BUILDING.
 SECTION 1028.1 OF FLORIDA BUILDING CODE, BUILDING,
 STATES THAT AT LEAST 50% OF THE REQUIRED EXITS SHALL
 DISCHARGE TO THE EXTERIOR OF THE BUILDING. THE ROUTE
 FROM STAIR #4 IS NOT CURRENTLY SHOWN AS A PROTECTED
 EXIT PASSAGEWAY.
  
 5. LOCATION OF ACCESSIBLE PARKING SPACES. PER FAIR
 HOUSING ACT AND SECTION 208.3 OF FLORIDA ACCESSIBILITY
 CODE, ACCESSIBLE PARKING SPACES ARE TO BE LOCATED ON
 THE SHORTEST POSSIBLE ROUTE OF TRAVEL FROM ADJACENT
 PARKING TO AN ACCESSIBLE ENTRANCE. THE DESIGN OF
 ACCESSIBLE PARKING SPACES SHALL COMPLY WITH SECTION 502
 OF FLORIDA ACCESSIBILITY CODE. THE FOLLOWING ACCESSIBLE
 PARKING SPACES ARE EITHER NOT USEABLE OR NOT LOCATED AS
 THE CLOSEST SPACE TO THE BUILDING ENTANCE:
 - SHEET A-1.2 ACCESSIBLE PARKING SPACE #61 IS NOT
 USABLE BECAUSE IT DOES NOT HAVE ACCESS TO ELEVATORS AS
 THE ELEVATORS ARE NO SHOW TO STOP ON THE 2ND LEVEL.
 - SHEET A-1.3 ACCESSIBLE PARKING SPACE #89 IS NOT
 USABLE BECAUSE THE ROUTE TO THE ELEVATOR GOES ACROSS
 THE STAIR LANDING AND THE LANDING DOORS DO NOT HAVE THE
 REQUIRED 48 INCH DOOR SWING SEPARATION REQUIRED BY
 SECTION 404.2.6 OF FLORIDA ACCESSIBILITY CODE.
 - SHEET A-1.4 ACCESSIBLE PARKING SPACE #171 IS NOT
 USABLE BECAUSE THE USER WOULD BE REQUIRED TO TRAVEL IN
 THE VEHICULAR DRIVE LANE TO GET TO THE ELEVATORS.
 - SHEET A-1.5 ACCESSIBLE PARKING SPACE #255 IS NOT
 USABLE BECAUSE THE ROUTE TO THE ELEVATOR GOES ACROSS
 THE STAIR LANDING AND THE LANDING DOORS DO NOT HAVE THE
 REQUIRED 48 INCH DOOR SWING SEPARATION REQUIRED BY
 SECTION 404.2.6 OF FLORIDA ACCESSIBILITY CODE.
 - SHEET A-1.4 ACCESSIBLE PARKING SPACE #320 IS NOT
 USABLE BECAUSE THE USER WOULD BE REQUIRED TO TRAVEL IN
 THE VEHICULAR DRIVE LANE TO GET TO THE ELEVATORS.
 - SHEET A-1.5 ACCESSIBLE PARKING SPACE #372 IS NOT
 USABLE BECAUSE THE ROUTE TO THE ELEVATOR GOES ACROSS
 THE STAIR LANDING AND THE LANDING DOORS DO NOT HAVE THE
 REQUIRED 48 INCH DOOR SWING SEPARATION REQUIRED BY
 SECTION 404.2.6 OF FLORIDA ACCESSIBILITY CODE.
  
 6. VAN ACCESSIBLE PARKING SPACES. THE BUILDING DATA
 TABLE ON SHEET A-1.0 STATES THAT TWO VAN ACCESSIBLE
 PARKING SPACES ARE BEING PROVIDED BUT THE LOCATION OF
 THE TWO SPACES IS NOT SHOWN ON THE PLANS. PER SECTION
 208.2.4 OF FLORIDA ACCESSIBILITY CODE, ONE IN EVERY SIX
 REQUIRED ACCESSIBLE SPACES (AT LEAST ONE) IN A PARKING
 STRUCTURE, SHALL BE ?VAN ACCESSIBLE? AND DESIGNED IN
 ACCORDANCE WITH SECTION OF 502 OF FLORIDA ACCESSIBILITY
 CODE (VERTICAL CLEARANCE NOT LESS THAN 98 INCHES AT
 SPACE AND VEHICULAR ACCESS ROUTE)
  
 7. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT,
 THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR
 THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT,
 AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE
 FLORIDA BUILDING CODE.
  
 8. ENCLOSED PARKING GARAGES. IF THE PARKING GARAGE DOES
 NOT HAVE WALL OPENINGS, OR SUFFICIENT WALL OPENINGS TO
 MEET THE DEFINITION OF AN OPEN PARKING GARAGE, IT WILL
 BE CONSIDERED AN ENCLOSED PARKING GARAGE AND MUST HAVE
 EXHAUST SYSTEMS. THE EXHAUST SYSTEMS SHALL BE DESIGNED
 TO MINIMIZE NOISE LEVELS USING INLINE FAN SILENCERS OR
 OTHER APPROVED METHODS.
  
 9. GREASE INTERCEPTOR. A GREASE INTERCEPTOR WILL BE
 REQUIRED. PLEASE CONTACT JEFFREY ODOMS, UTILITIES O&M
 SUPERINTENDENT, PUBLIC UTILITIES DEPARTMENT, FATS OILS
 AND GREASE DIVISION, AT (561) 822-2172, OR BY EMAIL:
 [email protected]
  
 10. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS
 AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE
 WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED
 FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS,
 GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND
 OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS,
 SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC.
  
 11. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT
 WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL
 HAVE A SEPARATE ADDRESS. FOR STREET ADDRESSING, CONTACT
 MICHAEL ORIO, GIS SUPPORT SPECIALIST, AT (561) 494
 1080, OR BY EMAIL: [email protected]
  
 12. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT
 TO ART IN PUBLIC PLACES (AIPP) ASSESSMENT. FOR ADVICE
 ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP
 ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC
 PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL:
 [email protected]
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  