Date |
Text |
2018-06-01 16:49:42 | GENERAL COMMENTS: |
| |
| 1.) PLEASE ENSURE ALL PLAN PACKETS HAVE A SIGNED AND |
| SEALED SURVEY. |
| |
| 2.) DISCUSSION REGARDING THE INTERNAL PEDESTRIAN |
| CROSSWALK MUST OCCUR PRIOR TO PLANNING BOARD. |
| |
| |
| MASTER DEVELOPMENT PLAN (SHEET MP-1) COMMENTS: |
| |
| 1.) THE FUTURE PROPOSED HOTEL USE HAS AN FAR OF 0.21, |
| WHICH MEANS THAT A MAXIMUM BUILDING POTENTIAL OF 80,836 |
| SQ. FT. HAS BEEN ESTABLISHED FOR THE USE. THIS MAXIMUM |
| BUILDING POTENTIAL SHOULD BE REFERENCED IN THE OVERALL |
| DEVELOPMENT SITE DATA TABULAR AND IN THE MASTER |
| DEVELOPMENT SITE PLAN. |
| |
| 2.) TRACT #2 IN THE MASTER DEVELOPMENT SITE PLAN SHALL |
| REFLECT THE LATEST CHANGES APPROVED BY THE TPS LETTER |
| ISSUED ON APRIL 4, 2018, BY THE PALM BEACH COUNTY |
| DEPARTMENT OF PUBLIC WORKS AND ENGINEERING - TRAFFIC |
| DIVISION. (I.E. BUILDING POTENTIAL OF UP TO 2,420 SQ. |
| FT. FOR THE PROPOSED RESTAURANT PARCEL) |
| |
| 3.) THE HEADER WITHIN THE PLAN SHOULD REFERENCE PALMS |
| GATEWAY COMMERCIAL PLANNED DEVELOPMENT (NOT EXTRA SPACE |
| STORAGE). PLEASE ADDRESS. |
| |
| |
| SITE PLAN COMMENTS: |
| |
| 1.) BICYCLE RACK SHALL BE LOCATED NEAR THE ENTRANCE OF |
| THE BUILDING AS PRACTICABLE. [ZLDR S.94-485(Q)] |
| [5/18/18 PPRC COMMENT NOT ADDRESSED] |
| |
| 2.) THE DETAIL OF THE DUMPSTER ENCLOSURE DOES NOT MEET |
| THE MINIMUM DIMENSIONAL STANDARDS OF THE ZLDRS. PLEASE |
| ADDRESS. [ZLDR S.94-315] |
| |
| 3.) WITH REFERENCE TO PPRC RESPONSE #1 (RESUBMITTAL |
| DATED 5/25/2018), RAISED LANDSCAPE PLANTERS WILL BE |
| PROVIDED ALONG THE OUTDOOR SEATING AREA. PLEASE INCLUDE |
| A DETAIL OF THE PROPOSED PLANTERS IN THE PLAN PACKET. |
| |
| 4.) PLEASE PROVIDE DIMENSIONS FOR THE PROPOSED LOADING |
| ZONE IN THE SITE PLAN. IT SHOULD BE NOTED THAT THE |
| DIMENSIONS PROVIDED IN THE TABULAR DOES NOT MATCH THE |
| DIMENSIONS MEASURED IN THE SITE PLAN. PLEASE ADDRESS |
| FOR CONSISTENCY. |
| |
| 5.) SHOW THE PROPOSED LIGHT POLE FIXTURES IN THE SITE |
| PLAN. PLEASE ENSURE THAT THE LOCATION OF THE POLES ARE |
| CONSISTENT WITH THE PHOTOMETRIC PLAN. ALSO, DEMONSTRATE |
| THAT THE POLES WILL NOT INTERFERE WITH VEHICULAR |
| PARKING/MOVEMENT BY PROVIDING A DETAIL OF THE PARKING |
| STALL STRIPING AND THE LOCATION OF THE POLE FIXTURE. |
| |
| 6.) CHECK DIMENSIONS FOR THE HANDICAPPED AND STANDARD |
| PARKING STALLS IN THE SITE DATA TABULAR. THERE SEEMS TO |
| BE INCORRECT INFORMATION PROVIDED ON THE DIMENSIONS. |
| |
| 7.) WHY IS THERE A GARBAGE CAN AND BENCH DETAIL IN THE |
| PLANS ON SHEET D-1? THERE DOES NOT SEEM TO BE ANY |
| BENCHES OR GARBAGE CAN PROVIDED ON THE RESTAURANT |
| PARCEL. |
| |
| |
| LANDSCAPE (SHEETS L-1 AND L-2) COMMENTS: |
| |
| 1.) THE WALLS OF THE DUMPSTER ENCLOSURE SHALL BE FULLY |
| LANDSCAPED WITH SHRUBS AND HEDGES PLANTED AT 2 FT. |
| INTERVALS. [ZLDR S.94-315] [5/18/18 PPRC COMMENT NOT |
| ADDRESSED] |
| |
| 2.) SHOW ALL LANDSCAPE BUFFERS THAT HAD PREVIOUSLY BEEN |
| APPROVED FOR THE CPD. THIS INFORMATION IS MISSING FROM |
| THE CURRENT SUBMITTAL. [5/18/18 PPRC COMMENT NOT |
| ADDRESSED] |
| |
| 3.) ADDITIONAL COMMENTS TO BE PROVIDED BY THE CITY'S |
| LANDSCAPE PLANNER. |
| |
| |
| ARCHITECTURAL PLANS (FLOOR PLAN AND ELEVATIONS): |
| |
| 1.) APPLICANT HAD NOTED THAT MECHANICAL EQUIPMENT, SUCH |
| AS THE A/C UNIT, WILL BE LOCATED ON THE ROOFTOP OF THE |
| PROPOSED RESTAURANT BUILDING; HOWEVER, IT IS NOT CLEAR |
| TO HOW THE MECHANICAL EQUIPMENT WILL BE SCREENED FROM |
| PUBLIC VIEW. PLEASE DEMONSTRATE HOW THE MECHANICAL |
| EQUIPMENT WILL BE SCREENED. AT MINIMUM, THERE SHOULD BE |
| A NOTE IN THE PLANS THAT ALL MECHANICAL EQUIPMENT WILL |
| BE SCREENED FROM VIEW BY THE BUILDING PARAPET OR WALL. |
| |
| PHOTOMETRICS: |
| |
| 1.) LOCATION OF LIGHT FIXTURES SHALL BE PROVIDED ON ALL |
| PLANS FOR CONSISTENCY AND TO ENSURE THAT THE FIXTURES |
| ARE NOT BE IN CONFLICT WITH EXISTING/PROPOSED SITE |
| ELEMENTS. [5/18/18 PPRC COMMENT NOT ADDRESSED] |
| |
| |
| INSTRUCTIONS FOR RESUBMITTAL: |
| |
| * PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN |
| WRITTEN FORMAT. |
| |
| * WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF |
| FIFTEEN (15) PAPER COPIES, ONE (1) REDUCED COPY IN 8.5 |
| INCHES X 11 INCHES AND ONE (1) SET IN 11 INCHES X 17 |
| INCHES, AND AN ELECTRONIC COPY OF ALL PLANS. PLEASE |
| NOTE THAT CHANGES ON THE RESUBMITTED PLANS MAY RESULT |
| IN ADDITIONAL COMMENTS. |
| |
| * PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) |
| RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED |
| COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE |
| APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE |
| WILL BE 20 PERCENT ($600) OF THE ORIGINAL APPLICATION |
| FEE. [NOTE: THE $600 RESUBMITTAL FEE WILL APPLY TO THE |
| NEXT RESUBMITTAL] |
| |
| * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE |
| QUESTIONS. |
| |
|
Print |