Notes |
Date |
Text |
2018-06-08 11:59:57 | DEL TACO RESUBMITTAL 2018-05-25 (Z18040017) | | | | - PROVIDE SUFFICIENT SIGHT DISTANCE AT THE | | DRIVE-THROUGH EXITS. AT THE EXIT AT THE DRIVE-THROUGH | | BEND, SIGHT DISTANCE LOOKING NORTH IS BLOCKED BY THE | | DUMPSTER. AT THE EXIT AT THE END OF THE DRIVE-THROUGH | | AISLE, SIGHT DISTANCE LOOKING WEST MAY BE BLOCKED BY | | THE RETAINING WALL DEPENDING ON THE HEIGHT OF THE WALL. | | - AT THE EXIT AT THE DRIVE-THROUGH BEND, IT APPEARS THE | | RADIUS IS STILL VERY TIGHT FOR A PASSENGER CAR TO MAKE | | A RIGHT-TURN. PLEASE REVISE AND VERIFY BY SHOWING | | AUTOTURN PATH FOR THIS MOVEMENT. | | - PROPOSED SIDEWALK FROM BELVEDERE IS SHOWN AS 4' WIDE. | | SIDEWALK MUST BE 5' WIDE. | | - CHECK IF HANDRAIL IS REQUIRED FOR SIDEWALK NEXT TO | | RETENTION AREA DUE TO DROP OFF. | | | | ERIK D. FERGUSON, P.E. |
|