Plan Review Notes
Plan Review Notes For Project Z18040017
Project Number Z18040017
Review Stop TRAFFIC
Sequence Number 1
Notes
Date Text
2018-05-08 17:23:04- PROVIDE TRAFFIC IMPACT STUDY IN ACCORDANCE WITH CITY
 CODE SECTION 94-311 OR DOCUMENTATION DEMONSTRATING THAT
 CITY CODE SECTION 94-311(C) TRAFFIC IMPACT STUDY
 REQUIRED IS NOT APPLICABLE.
 - 8' RADIUS ON LANDSCAPE TERMINAL ISLANDS IS
 INSUFFICIENT TO ALLOW A PASSENGER TO TURN WHILE STAYING
 IN ITS OWN TRAVEL LANE.
 - WHERE IS THE ACCESSIBLE PEDESTRIAN ROUTE FROM THE
 DRIVEWAY ON BELVEDERE ROAD TO THE SITE?
  
 UPDATED 5/14/2018
 IT IS UNCLEAR HOW THE DRIVE-THROUGH TRAFFIC WOULD
 MANEUVER THROUGH THE SITE. HERE ARE SOME
 RECOMMENDATIONS FOR CONSIDERATION TO ENSURE A SAFE AND
 EFFICIENT OPERATION: INSTALL STOP BAR, STOP SIGN, AND
 REGULATOR/PROHIBITIVE SIGN AT THE END OF THE
 DRIVE-THROUGH DRIVEWAY; REVISE THE CURB RADIUS
 (CURRENTLY SHOWN WITH A 5-FT RADIUS) IF DRIVERS
 EXISTING THE DRIVE-THROUGH ARE EXPECTING TO MAKE A
 RIGHT; PROVIDE ADEQUATE SIGHT DISTANCES FOR ALL
 MOVEMENT.
  
  
 ERIK D. FERGUSON, PE
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  