Plan Review Notes
Plan Review Notes For Project Z10050014
Project Number Z10050014
Review Stop SURVEY
Sequence Number 1
Notes
Date Text
2010-06-07 14:47:121. NO PROPERTY CORNERS SHOWN AS FOUND OR SET.
 2. NO BEARING BASE. TYPE AND HEIGHT OF FENCE NOT
 DESCRIBED.
 3. NO BENCHMARK INFORMATION SHOWN.
 4. ALTA SURVEY NEEDS TO BE CERTIFIED MEETING ALTA
 STANDARDS. THIS SURVEY DOES NOT MEET ALTA STANDARDS NOR
 MTS.
 5. APPLICATION FOR PROPOSED UTILITY EASEMENT IS THRU
 ENGINEERING SERVICES.
 6. UNITY OF TITLE WILL BE REQUIRED.
 7. ELEVATIONS ON SURVEY DO NOT MATCH ELEVATIONS ON
 ENGINEERING PLANS.