Plan Review Details - Project Z18040017
Plan Review Stops For Project Z18040017 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
06-04-2018 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
06-04-2018 |
Time |
12:58 |
Rev Time |
0.00 |
Received By |
mgonzale |
Date |
06-04-2018 |
Time |
12:58 |
Sent To |
|
|
Notes |
2018-06-04 13:04:54 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | COMMENTS: | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | 2. FLOOD ZONE. ACCORDING TO THE ADOPTED FLOOD INSURANCE | | RATE MAPS (FIRMS), THE PROPOSED BUILDING IS IN FLOOD | | ZONE AE, WITH A BASE FLOOD ELEVATION OF 12.7 FT NAVD. | | THE FIRST FLOOR OF THE BUILDING AND ALL ASSOCIATED | | MECHANICAL EQUIPMENT (CHILLERS, GENERATORS ETC.) SHALL | | BE 24 INCHES (FREEBOARD) ABOVE THE BASE FLOOD | | ELEVATION. | | | | 3. ACCESSIBLE ROUTE. COMMENT ADDRESSED BY REVISED SITE | | PLAN LAYOUT C-5, REVISION 1 - THE PLANS NOW SHOW AN | | ACCESSIBLE WHEELCHAIR AND PEDESTRIAN ROUTE FROM THE | | PUBLIC RIGHT-OF-WAY COMPLYING WITH SECTIONS 206.2 AND | | 402.2 OF FLORIDA ACCESSIBILITY CODE, FROM THE PUBLIC | | RIGHT-OF-WAY TO ALL ACCESSIBLE BUILDING OR FACILITY | | ENTRANCES. | | | | 4. NUMBER OF ACCESSIBLE PARKING SPACES. COMMENT | | ADDRESSED BY REVISED SITE PLAN LAYOUT C-5, REVISION 1 - | | THE PLANS NOW SHOW 2 ACCESSIBLE PARKING SPACES AS | | REQUIRED TO COMPLY WITH SECTION 208.2 OF FLORIDA | | ACCESSIBILITY CODE. | | | | 5. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | FLORIDA BUILDING CODE. | | | | 6. GREASE INTERCEPTOR. A GREASE INTERCEPTOR WILL BE | | REQUIRED. PLEASE CONTACT JEFFREY ODOMS, UTILITIES O&M | | SUPERINTENDENT, PUBLIC UTILITIES DEPARTMENT, FATS OILS | | AND GREASE DIVISION, AT (561) 822-2172, OR BY EMAIL: | | [email protected] | | | | 7. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, | | FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, | | GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, | | SITE IRRIGATION, ETC. | | | | | | ROBERT BROWN | | BUILDING OFFICIAL | | TEL: 561 805 6652 | | EMAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
05-08-2018 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
05-08-2018 |
Time |
19:22 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
05-08-2018 |
Time |
19:22 |
Sent To |
|
|
Notes |
2018-05-08 19:32:54 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | COMMENTS: | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | 2. FLOOD ZONE. ACCORDING TO THE ADOPTED FLOOD INSURANCE | | RATE MAPS (FIRMS), THE PROPOSED BUILDING IS IN FLOOD | | ZONE AE, WITH A BASE FLOOD ELEVATION OF 12.7 FT NAVD. | | THE FIRST FLOOR OF THE BUILDING AND ALL ASSOCIATED | | MECHANICAL EQUIPMENT (CHILLERS, GENERATORS ETC.) SHALL | | BE 24 INCHES (FREEBOARD) ABOVE THE BASE FLOOD | | ELEVATION. | | | | 3. ACCESSIBLE ROUTE. THE PLANS DO NOT SHOW AN | | ACCESSIBLE WHEELCHAIR AND PEDESTRIAN ROUTE FROM THE | | PUBLIC RIGHT-OF-WAY. WHEN SUBMITTED FOR PERMIT, THE | | PLANS SHALL SHOW AT LEAST ONE ACCESSIBLE ROUTE, | | COMPLYING WITH SECTIONS 206.2 AND 402.2 OF FLORIDA | | ACCESSIBILITY CODE, FROM THE PUBLIC RIGHT-OF-WAY TO ALL | | ACCESSIBLE BUILDING OR FACILITY ENTRANCES. | | | | 4. NUMBER OF ACCESSIBLE PARKING SPACES. THE PLANS SHOW | | ONLY ONE ACCESSIBLE PARKING SPACE. A TOTAL OF 26 | | PARKING SPACES ARE PROPOSED SO 2 ACCESSIBLE PARKING | | SPACES ARE REQUIRED. THE MINIMUM NUMBER OF ACCESSIBLE | | PARKING SPACES PROVIDED SHALL BE IN ACCORDANCE WITH | | SECTION 208.2 OF FLORIDA ACCESSIBILITY CODE. | | | | 5. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | FLORIDA BUILDING CODE. | | | | 6. GREASE INTERCEPTOR. A GREASE INTERCEPTOR WILL BE | | REQUIRED. PLEASE CONTACT JEFFREY ODOMS, UTILITIES O&M | | SUPERINTENDENT, PUBLIC UTILITIES DEPARTMENT, FATS OILS | | AND GREASE DIVISION, AT (561) 822-2172, OR BY EMAIL: | | [email protected] | | | | 7. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, | | FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, | | GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, | | SITE IRRIGATION, ETC. | | | | | | ROBERT BROWN | | BUILDING OFFICIAL | | TEL: 561 805 6652 | | EMAIL: [email protected] | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
P |
Date |
06-07-2018 |
|
|
Cont ID |
|
Sent By |
mgonzale |
Date |
06-07-2018 |
Time |
16:00 |
Rev Time |
0.50 |
Received By |
mgonzale |
Date |
06-07-2018 |
Time |
16:00 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
Rev No |
1 |
Status |
P |
Date |
05-09-2018 |
|
|
Cont ID |
|
Sent By |
Mgonzale |
Date |
05-09-2018 |
Time |
|
Rev Time |
1.00 |
Received By |
mgonzale |
Date |
05-09-2018 |
Time |
|
Sent To |
I |
|
Notes |
2018-05-09 11:24:30 | RESPOND TO COMMENTS IN WRITING: | | | | 1. DUMSPTER AREA MUST MEET CITY'S MINIMUM DIMENSIONS. | | LOCATION AND ANGLE APPEAR TO BE DIFFICULT FOR TRUCK | | ACCESS. | | CONTACT CITY OF WPB SANITATION FOR TRUCK DIMENSIONS AND | | PARAMETERS. | | | | 2. COUNTY WATER AND SEWER APPROVAL WILL BE REQUIRED. | | | | 3. REVIEW PARKING STOP BARS AND STOP SIGNS, SOME MAY BE | | MISSING. | | | | MANNY GONZALEZ | | SENIOR ENGINEERING PROJECT COORDINATOR | | PUBLIC WORKS DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 | | DIRECT: (561) 494-1085 | | FAX: (561) 494-1116 | | EMAIL: [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
05-08-2018 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
05-08-2018 |
Time |
16:00 |
Rev Time |
0.00 |
Received By |
pleduc |
Date |
05-08-2018 |
Time |
15:50 |
Sent To |
|
|
Notes |
2018-05-08 15:59:50 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | BEACH FIRE RESCUE. | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | ARE SUBMITTED FOR PERMIT. | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | PROPOSED PROJECT. | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | PROTECTION. | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | ALL CONSTRUCTION ACTIVITIES. | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | THE 6TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE THE | | OCCUPANCY TYPE, PER THE FLORIDA FIRE PREVENTION CODE, | | AND WHETHER IT IS MIXED OR SEPARATED OCCUPANCY. | | | | 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT A FIRE | | LOAD CALCULATION IS INCLUDED AND THAT ADEQUATE WATER | | SUPPLY IS EXISTING OR WILL BE PROVIDED. | | | | 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | FIRE PREVENTION. | | ALL NEW FIRE HYDRANTS AND FDC?S PLANNED FOR THIS | | DEVELOPMENT SHALL BE CLOSELY COORDINATED WITH THE | | BUREAU OF FIRE PREVENTION. PROPOSED FIRE HYDRANTS AND | | FDC?S SHOULD BE LOCATED ON THE SAME SIDE OF THE STREET | | OR ACCESS ROADWAY TO ALLOW FREE ACCESS FOR OTHER | | ARRIVING EMERGENCY VEHICLES. | | | | 9. IF FIRE SPRINKLERS OR FIRE ALARM IS REQUIRED PER THE | | APPLICABLE OCCUPANCY CODE, ENSURE THEY COMPLY WITH THE | | REQUIREMENTS OF FS 61G AND SUBMITT WITH THE MASTER | | PLAN. | | | | 10. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | SAFETY FEATURES AND EQUIPMENT. | | | | 11. IT IS HIGHLY RECOMMENDED (REQUIRED WITH FIRE | | SPRINKLER SYSTEM) THAT A KNOX BOX WITH KEYS FOR ENTRY | | DOOR LOCKS BE PROVIDED FOR 24 HOUR EMERGENCY ACCESS. | | | | 12. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | DOES NOT CONSTITUTE ITS FINAL REVIEW OR APPROVAL. | | | | 13. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
3 |
Status |
P |
Date |
06-26-2018 |
|
|
Cont ID |
|
Sent By |
rcaranci |
Date |
06-26-2018 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
rcaranci |
Date |
06-26-2018 |
Time |
15:57 |
Sent To |
|
|
Notes |
2018-06-26 16:02:55 | | | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | PROJECT: PALMS GATEWAY PD LOT 2 DEL TACO Z18040017 | | JUNE 26, 2018 | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. PLEASE SHOW THE REQUIRED 5 FOOT LANDSCAPE | | BUFFER PLANTINGS ALONG THE EAST PROPERTY LINE AS | | APPROVED WITH THE PD. THE BUFFER SECTION INCLUDED WITH | | THIS LOT IS PART OF THE LOT LANDSCAPING. ALSO SHOW THE | | CURB LOCATION. | | | | THE LANDSCAPE BUFFER IS SHOWN, BUT THE ONLY EXISTING | | PORTION IS AT THE NORTH END, AND CONSISTS OF 3 TRIPLE | | ADONIDIA PALMS. PLEASE CORRECT TO INCLUDE THE TREES AND | | HEDGE TO BE INSTALLED ON THIS LOT. | | | | 2. SATISFIED. PLEASE INCLUDE ALL CALCULATIONS FOR THE | | EAST BUFFER PORTION ON THE LANDSCAPE REQUIREMENT CHART | | AND THE PLANT LIST. | | PLEASE CORRECT FOR ALL TO BE INSTALLED. | | | | 3. SATISFIED. PLEASE UPDATE THE LANDSCAPE CALCULATIONS | | TO CURRENT CODE REQUIREMENTS OF 1500 SQ FT FOR SHADE | | TREES AND 6000 SQ FT FOR FLOWERING TREES. | | CORRECT THE REQUIRED TREES TO 14 AND FLOWERING TREES TO | | 4, AS ANY PORTION REQUIRES TO ROUND UP. | | | | 4. SATISFIED. PLEASE INCLUDE ANY EXISTING TREES OR | | LANDSCAPE ON THE PLANT LIST IDENTIFYING THE SPECIES AND | | SHOW AS EXISTING. THIS INCLUDES THE NORTH BUFFER. | | | | 5. SATISFIED. PLEASE CORRECT THE FLORIDA FRIENDLY | | LANDSCAPE CHART TO CURRENT CODE, AND PROVIDE REQUIRED | | 50 POINTS. | | 6. SATISFIED. PLEASE SHOW COMPLIANCE WITH SECTION | | 94-445 L. PLANT SPECIES. A MINIMUM OF 60 PERCENT OF | | PLANT MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | FLORIDA LANDSCAPES. | | | | 7. SATISFIED. PLEASE ADD COLUMNS TO THE PLANT LIST FOR | | NATIVE (Y OR N) AND DROUGHT TOLERANCE (HIGH, MEDIUM OR | | LOW). | | CARISSA AND PERENNIAL PEANUT ARE NOT FLORIDA NATIVE | | PLANTS. | | | | 8. SATISFIED. PLEASE SHOW LOCATIONS OF ROOT BARRIERS | | FOR WATER AND SEWER LINES ON THE LANDSCAPE PLAN AND | | PROVIDE A DETAIL. | | ADDITIONAL COMMENTS 6/1/18: | | 9. SATISFIED. PLEASE CORRECT THE CAD ISSUE WITH THE | | NAMES ON THE PLANT LIST. | | | | 10. SATISFIED. LANDSCAPE ADJUSTMENTS MADE TO | | ACCOMMODATE THE ADA SIDEWALK CONNECTION TO BELVEDERE AS | | PROPOSED ARE ACCEPTABLE IF THE MAHOGANY IN THE BUFFER | | IS RELOCATED TO REPLACE A ROYAL PALM IN THE NORTH | | BUFFER AND THE ROYAL MOVED TO THE PROPOSED LOCATION | | WEST OF THE SIGN. | | | | CONDITIONS OF APPROVAL: | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | SERVICES DEPARTMENT, PLANNING DIVISION. | | |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
2 |
Status |
F |
Date |
06-01-2018 |
|
|
Cont ID |
|
Sent By |
rcaranci |
Date |
06-01-2018 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
rcaranci |
Date |
06-01-2018 |
Time |
15:16 |
Sent To |
|
|
Notes |
2018-06-01 15:17:24 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | PROJECT: PALMS GATEWAY PD LOT 2 DEL TACO Z18040017 | | JUNE 1, 2018 | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. PARTIALLY SATISFIED. PLEASE SHOW THE REQUIRED 5 FOOT | | LANDSCAPE BUFFER PLANTINGS ALONG THE EAST PROPERTY LINE | | AS APPROVED WITH THE PD. THE BUFFER SECTION INCLUDED | | WITH THIS LOT IS PART OF THE LOT LANDSCAPING. ALSO SHOW | | THE CURB LOCATION. | | | | THE LANDSCAPE BUFFER IS SHOWN, BUT THE ONLY EXISTING | | PORTION IS AT THE NORTH END, AND CONSISTS OF 3 TRIPLE | | ADONIDIA PALMS. PLEASE CORRECT TO INCLUDE THE TREES AND | | HEDGE TO BE INSTALLED ON THIS LOT. | | | | 2. PARTIALLY SATISFIED. PLEASE INCLUDE ALL CALCULATIONS | | FOR THE EAST BUFFER PORTION ON THE LANDSCAPE | | REQUIREMENT CHART AND THE PLANT LIST. | | PLEASE CORRECT FOR ALL TO BE INSTALLED. | | | | 3. PARTIALLY SATISFIED. PLEASE UPDATE THE LANDSCAPE | | CALCULATIONS TO CURRENT CODE REQUIREMENTS OF 1500 SQ FT | | FOR SHADE TREES AND 6000 SQ FT FOR FLOWERING TREES. | | CORRECT THE REQUIRED TREES TO 14 AND FLOWERING TREES TO | | 4, AS ANY PORTION REQUIRES TO ROUND UP. | | | | 4. SATISFIED. PLEASE INCLUDE ANY EXISTING TREES OR | | LANDSCAPE ON THE PLANT LIST IDENTIFYING THE SPECIES AND | | SHOW AS EXISTING. THIS INCLUDES THE NORTH BUFFER. | | | | 5. SATISFIED. PLEASE CORRECT THE FLORIDA FRIENDLY | | LANDSCAPE CHART TO CURRENT CODE, AND PROVIDE REQUIRED | | 50 POINTS. | | 6. SATISFIED. PLEASE SHOW COMPLIANCE WITH SECTION | | 94-445 L. PLANT SPECIES. A MINIMUM OF 60 PERCENT OF | | PLANT MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | FLORIDA LANDSCAPES. | | | | 7. PARTIALLY SATISFIED. PLEASE ADD COLUMNS TO THE PLANT | | LIST FOR NATIVE (Y OR N) AND DROUGHT TOLERANCE (HIGH, | | MEDIUM OR LOW). | | CARISSA AND PERENNIAL PEANUT ARE NOT FLORIDA NATIVE | | PLANTS. | | | | 8. SATISFIED. PLEASE SHOW LOCATIONS OF ROOT BARRIERS | | FOR WATER AND SEWER LINES ON THE LANDSCAPE PLAN AND | | PROVIDE A DETAIL. | | ADDITIONAL COMMENTS 6/1/18: | | 9. PLEASE CORRECT THE CAD ISSUE WITH THE NAMES ON THE | | PLANT LIST. | | | | 10. LANDSCAPE ADJUSTMENTS MADE TO ACCOMMODATE THE ADA | | SIDEWALK CONNECTION TO BELVEDERE AS PROPOSED ARE | | ACCEPTABLE IF THE MAHOGANY IN THE BUFFER IS RELOCATED | | TO REPLACE A ROYAL PALM IN THE NORTH BUFFER AND THE | | ROYAL MOVED TO THE PROPOSED LOCATION WEST OF THE SIGN. | | | | CONDITIONS OF APPROVAL: | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | SERVICES DEPARTMENT, PLANNING DIVISION. | | |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
1 |
Status |
F |
Date |
05-04-2018 |
|
|
Cont ID |
|
Sent By |
rcaranci |
Date |
05-04-2018 |
Time |
11:26 |
Rev Time |
0.00 |
Received By |
rcaranci |
Date |
05-04-2018 |
Time |
11:26 |
Sent To |
|
|
Notes |
2018-05-04 11:28:10 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | PROJECT: PALMS GATEWAY PD LOT 2 DEL TACO Z18040017 | | MAY 4, 2018 | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. PLEASE SHOW THE REQUIRED 5 FOOT LANDSCAPE BUFFER | | PLANTINGS ALONG THE EAST PROPERTY LINE AS APPROVED WITH | | THE PD. THE BUFFER SECTION INCLUDED WITH THIS LOT IS | | PART OF THE LOT LANDSCAPING. ALSO SHOW THE CURB | | LOCATION. | | | | 2. PLEASE INCLUDE ALL CALCULATIONS FOR THE EAST BUFFER | | PORTION ON THE LANDSCAPE REQUIREMENT CHART AND THE | | PLANT LIST. | | | | 3. PLEASE UPDATE THE LANDSCAPE CALCULATIONS TO CURRENT | | CODE REQUIREMENTS OF 1500 SQ FT FOR SHADE TREES AND | | 6000 SQ FT FOR FLOWERING TREES. | | | | 4. PLEASE INCLUDE ANY EXISTING TREES OR LANDSCAPE ON | | THE PLANT LIST IDENTIFYING THE SPECIES AND SHOW AS | | EXISTING. THIS INCLUDES THE NORTH BUFFER. | | | | 5. PLEASE CORRECT THE FLORIDA FRIENDLY LANDSCAPE CHART | | TO CURRENT CODE, AND PROVIDE REQUIRED 50 POINTS. | | 6. PLEASE SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT | | SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL | | ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT | | SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF | | SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA | | WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA | | LANDSCAPES. | | | | 7. PLEASE ADD COLUMNS TO THE PLANT LIST FOR NATIVE (Y | | OR N) AND DROUGHT TOLERANCE (HIGH, MEDIUM OR LOW). | | | | 8. PLEASE SHOW LOCATIONS OF ROOT BARRIERS FOR WATER AND | | SEWER LINES ON THE LANDSCAPE PLAN AND PROVIDE A DETAIL. | | |
|
|
Review Stop |
PARK |
PARKING |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
|
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
POLICE |
POLICE |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
|
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
PW |
PUBLIC WORKS |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
|
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
STORM |
STORMWATER |
Rev No |
2 |
Status |
P |
Date |
06-04-2018 |
|
|
Cont ID |
|
Sent By |
tward |
Date |
06-04-2018 |
Time |
07:54 |
Rev Time |
0.00 |
Received By |
tward |
Date |
06-04-2018 |
Time |
07:59 |
Sent To |
|
|
Notes |
2018-06-04 07:58:42 | THE FOLLOWING COMMENT IS FROM THE REVIEW OF THE MAY 25, | | 2018 REVIEW SUBMITTAL PACKAGE: | | | | 1. REVISED SURVEY WAS NOT PROVIDED. THE VERTICAL DATUM | | FOR THE FEMA FLOOD ELEVATION WAS MISSING. AS A | | CONDITION OF APPROVAL, THE VERTICAL DATUM FOR THE FEMA | | FLOOD ELEVATION NEEDS TO BE LABELED ALONG WITH THE | | CONVERSION TO NGVD 1929 IF THE VERTICAL DATUM IS | | ANYTHING OTHER THAN NGVD1929. | | | | TRACY L. WARD, P.E. | | SENIOR STORMWATER ENGINEER | | ENGINEERING SERVICES DEPARTMENT | | 561-494-1120 | | [email protected] |
|
|
Review Stop |
STORM |
STORMWATER |
Rev No |
1 |
Status |
F |
Date |
05-09-2018 |
|
|
Cont ID |
|
Sent By |
tward |
Date |
05-09-2018 |
Time |
12:56 |
Rev Time |
0.00 |
Received By |
tward |
Date |
05-09-2018 |
Time |
12:57 |
Sent To |
|
|
Notes |
2018-05-09 12:57:23 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT | | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT HTTP:// | | WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PER | | MITS-APPLICATIONS | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | PLAN APPROVAL: | | | | 1. ADD THE VERTICAL DATUM REFERENCE (NAVD 1988) TO THE | | AE FLOOD ZONE BFE NOTE (#7) ON THE SURVEY AND PROVIDE | | THE CORRESPONDING NGVD 1929 ELEVATION. PER NOTE #10 ON | | THE SURVEY, THE REMAINING ELEVATIONS ARE REFERENCED TO | | NGVD 1929. | | | | 2. BELVEDERE ROAD AND AUSTRALIAN AVE ARE MAINTAINED BY | | FDOT AND/OR PALM BEACH COUNTY. | | | | 3. TWO FEET OF FREEBOARD ABOVE BASE FLOOD ELEVATION IS | | REQUIRED FOR STRUCTURES IN SPECIAL FLOOD HAZARD AREAS. | | THE BFE FOR THE AE ZONE IS 12.7 FT NAVD 1988 (14.2 FT | | NGVD 1929) THE PROPOSED FFE IS 20.5 FT NGVD 1929) | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION MAY | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS | | CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE | | ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS | | | | 2. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED | | WITH THE ENGINEERING PERMIT APPLICATION. | | | | 3. PROVIDE A COPY OF THE SFWMD ERP PERMIT MODIFICATION | | FOR THE PROJECT. | | | | | | TRACY WARD, PE | | SENIOR STORMWATER ENGINEER | | ENGINEERING SERVICES DEPARTMENT | | 561-494-1120 | | [email protected] | | |
|
|
Review Stop |
SURVEY |
SURVEYING |
Rev No |
1 |
Status |
P |
Date |
05-07-2018 |
|
|
Cont ID |
|
Sent By |
vnoel |
Date |
05-07-2018 |
Time |
09:09 |
Rev Time |
|
Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
Rev No |
4 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
07-10-2018 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
2018-07-10 11:23:53 | PASSED BASED ON REVISED PLANS RECEIVED AND SIGNED AND | | SEALED ON 7/6/18. | | | | ERIK D. FERGUSON, PE | | CITY TRANSPORTATION ENGINEER |
|
|
Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
Rev No |
3 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
06-20-2018 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
2018-06-20 18:02:07 | DEL TACO RESUBMITTAL 2018-06-18 (Z18040017) | | | | | | - CONSIDER NARROWING THE NORTH-SOUTH INTERNAL ROADWAY | | IN FRONT OF THE DUMPSTER FROM 30 TO 22 FEET, WHICH WILL | | ALLOW THE STOP BAR AT THE EXIT AT THE DRIVE-THROUGH | | BEND TO BE SHIFTED EASTWARD, THUS IMPROVING SIGHT | | DISTANCE LOOKING NORTH FOR THE DRIVE THROUGH BYPASS | | LANE. THE EXTRA SPACE COULD BE CONVERTED TO 2 PARALLEL | | PARKING SPACES. ALSO, MODIFY THE PAVEMENT MARKING AT | | THE MEDIAN NOSE OF THE BELVEDERE DRIVEWAY TO ALIGN WITH | | THE NARROWED INTERNAL ROADWAY. | | - CONSIDER SHIFTING THE EAST-WEST CROSSWALK, FROM WAWA, | | SOUTHWARD TO ALIGN WITH THE SECOND ADA RAMP LANDING | | STRIP. 2 PARKING SPACES MAY NEED TO BE REMOVED BUT IS | | COMPENSATED BY 2 ADDITIONAL PARALLEL PARKING SPACES PER | | COMMENT ABOVE. THIS WOULD RESOLVE THE ISSUE OF THE | | CROSSWALK CONFLICTING WITH STOPPED CARS. | | - REMOVE THE LEFT-TURN ONLY SIGN AT THE EXIT OF THE | | DRIVE-THROUGH. THIS SIGN WAS NOT REQUESTED PREVIOUSLY. | | | | ERIK D. FERGUSON, P.E. | | CITY TRANSPORTATION ENGINEER |
|
|
Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
06-08-2018 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
2018-06-08 11:59:57 | DEL TACO RESUBMITTAL 2018-05-25 (Z18040017) | | | | - PROVIDE SUFFICIENT SIGHT DISTANCE AT THE | | DRIVE-THROUGH EXITS. AT THE EXIT AT THE DRIVE-THROUGH | | BEND, SIGHT DISTANCE LOOKING NORTH IS BLOCKED BY THE | | DUMPSTER. AT THE EXIT AT THE END OF THE DRIVE-THROUGH | | AISLE, SIGHT DISTANCE LOOKING WEST MAY BE BLOCKED BY | | THE RETAINING WALL DEPENDING ON THE HEIGHT OF THE WALL. | | - AT THE EXIT AT THE DRIVE-THROUGH BEND, IT APPEARS THE | | RADIUS IS STILL VERY TIGHT FOR A PASSENGER CAR TO MAKE | | A RIGHT-TURN. PLEASE REVISE AND VERIFY BY SHOWING | | AUTOTURN PATH FOR THIS MOVEMENT. | | - PROPOSED SIDEWALK FROM BELVEDERE IS SHOWN AS 4' WIDE. | | SIDEWALK MUST BE 5' WIDE. | | - CHECK IF HANDRAIL IS REQUIRED FOR SIDEWALK NEXT TO | | RETENTION AREA DUE TO DROP OFF. | | | | ERIK D. FERGUSON, P.E. |
|
|
Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
05-08-2018 |
Time |
|
Rev Time |
|
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
2018-05-08 17:23:04 | - PROVIDE TRAFFIC IMPACT STUDY IN ACCORDANCE WITH CITY | | CODE SECTION 94-311 OR DOCUMENTATION DEMONSTRATING THAT | | CITY CODE SECTION 94-311(C) TRAFFIC IMPACT STUDY | | REQUIRED IS NOT APPLICABLE. | | - 8' RADIUS ON LANDSCAPE TERMINAL ISLANDS IS | | INSUFFICIENT TO ALLOW A PASSENGER TO TURN WHILE STAYING | | IN ITS OWN TRAVEL LANE. | | - WHERE IS THE ACCESSIBLE PEDESTRIAN ROUTE FROM THE | | DRIVEWAY ON BELVEDERE ROAD TO THE SITE? | | | | UPDATED 5/14/2018 | | IT IS UNCLEAR HOW THE DRIVE-THROUGH TRAFFIC WOULD | | MANEUVER THROUGH THE SITE. HERE ARE SOME | | RECOMMENDATIONS FOR CONSIDERATION TO ENSURE A SAFE AND | | EFFICIENT OPERATION: INSTALL STOP BAR, STOP SIGN, AND | | REGULATOR/PROHIBITIVE SIGN AT THE END OF THE | | DRIVE-THROUGH DRIVEWAY; REVISE THE CURB RADIUS | | (CURRENTLY SHOWN WITH A 5-FT RADIUS) IF DRIVERS | | EXISTING THE DRIVE-THROUGH ARE EXPECTING TO MAKE A | | RIGHT; PROVIDE ADEQUATE SIGHT DISTANCES FOR ALL | | MOVEMENT. | | | | | | ERIK D. FERGUSON, PE | | CITY TRANSPORTATION ENGINEER | | 561-494-1092 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
07-17-2018 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
09-10-2018 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
09-17-2018 |
Time |
|
Sent To |
|
|
Notes |
2018-09-06 08:28:14 | CONDITIONS OF APPROVAL: | | | | 1.) NO BUILDING PERMITS FOR THE USES SPECIFIED IN THE | | REVISED TRAFFIC PERFORMANCE STANDARDS (TPS) REVIEW | | LETTER FROM THE PALM BEACH COUNTY TRAFFIC DIVISION | | (DATED APRIL 10, 2018), SHALL BE ISSUED AFTER DECEMBER | | 31, 2018. | | | | 2.) PRIOR TO THE REMOVAL AND RELOCATION OF ANY TREES ON | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | SERVICES DEPARTMENT - PLANNING DIVISION. | | | | 3.) ALL PRIVATE DEVELOPMENT PROJECTS, INCLUDING NEW | | CONSTRUCTION, OR THE RENOVATION OR IMPROVEMENT OF ANY | | EXISTING BUILDING, WHERE THE TOTAL CONSTRUCTION COSTS | | ARE EQUAL TO OR GREATER THAN $750,000 IS SUBJECT TO THE | | ART IN PUBLIC PLACES REQUIREMENTS OF CHAPTER 78, | | ARTICLE V, OF THE CITY'S CODE OF ORDINANCES. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
06-01-2018 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
06-01-2018 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
06-01-2018 |
Time |
|
Sent To |
|
|
Notes |
2018-06-01 16:49:42 | GENERAL COMMENTS: | | | | 1.) PLEASE ENSURE ALL PLAN PACKETS HAVE A SIGNED AND | | SEALED SURVEY. | | | | 2.) DISCUSSION REGARDING THE INTERNAL PEDESTRIAN | | CROSSWALK MUST OCCUR PRIOR TO PLANNING BOARD. | | | | | | MASTER DEVELOPMENT PLAN (SHEET MP-1) COMMENTS: | | | | 1.) THE FUTURE PROPOSED HOTEL USE HAS AN FAR OF 0.21, | | WHICH MEANS THAT A MAXIMUM BUILDING POTENTIAL OF 80,836 | | SQ. FT. HAS BEEN ESTABLISHED FOR THE USE. THIS MAXIMUM | | BUILDING POTENTIAL SHOULD BE REFERENCED IN THE OVERALL | | DEVELOPMENT SITE DATA TABULAR AND IN THE MASTER | | DEVELOPMENT SITE PLAN. | | | | 2.) TRACT #2 IN THE MASTER DEVELOPMENT SITE PLAN SHALL | | REFLECT THE LATEST CHANGES APPROVED BY THE TPS LETTER | | ISSUED ON APRIL 4, 2018, BY THE PALM BEACH COUNTY | | DEPARTMENT OF PUBLIC WORKS AND ENGINEERING - TRAFFIC | | DIVISION. (I.E. BUILDING POTENTIAL OF UP TO 2,420 SQ. | | FT. FOR THE PROPOSED RESTAURANT PARCEL) | | | | 3.) THE HEADER WITHIN THE PLAN SHOULD REFERENCE PALMS | | GATEWAY COMMERCIAL PLANNED DEVELOPMENT (NOT EXTRA SPACE | | STORAGE). PLEASE ADDRESS. | | | | | | SITE PLAN COMMENTS: | | | | 1.) BICYCLE RACK SHALL BE LOCATED NEAR THE ENTRANCE OF | | THE BUILDING AS PRACTICABLE. [ZLDR S.94-485(Q)] | | [5/18/18 PPRC COMMENT NOT ADDRESSED] | | | | 2.) THE DETAIL OF THE DUMPSTER ENCLOSURE DOES NOT MEET | | THE MINIMUM DIMENSIONAL STANDARDS OF THE ZLDRS. PLEASE | | ADDRESS. [ZLDR S.94-315] | | | | 3.) WITH REFERENCE TO PPRC RESPONSE #1 (RESUBMITTAL | | DATED 5/25/2018), RAISED LANDSCAPE PLANTERS WILL BE | | PROVIDED ALONG THE OUTDOOR SEATING AREA. PLEASE INCLUDE | | A DETAIL OF THE PROPOSED PLANTERS IN THE PLAN PACKET. | | | | 4.) PLEASE PROVIDE DIMENSIONS FOR THE PROPOSED LOADING | | ZONE IN THE SITE PLAN. IT SHOULD BE NOTED THAT THE | | DIMENSIONS PROVIDED IN THE TABULAR DOES NOT MATCH THE | | DIMENSIONS MEASURED IN THE SITE PLAN. PLEASE ADDRESS | | FOR CONSISTENCY. | | | | 5.) SHOW THE PROPOSED LIGHT POLE FIXTURES IN THE SITE | | PLAN. PLEASE ENSURE THAT THE LOCATION OF THE POLES ARE | | CONSISTENT WITH THE PHOTOMETRIC PLAN. ALSO, DEMONSTRATE | | THAT THE POLES WILL NOT INTERFERE WITH VEHICULAR | | PARKING/MOVEMENT BY PROVIDING A DETAIL OF THE PARKING | | STALL STRIPING AND THE LOCATION OF THE POLE FIXTURE. | | | | 6.) CHECK DIMENSIONS FOR THE HANDICAPPED AND STANDARD | | PARKING STALLS IN THE SITE DATA TABULAR. THERE SEEMS TO | | BE INCORRECT INFORMATION PROVIDED ON THE DIMENSIONS. | | | | 7.) WHY IS THERE A GARBAGE CAN AND BENCH DETAIL IN THE | | PLANS ON SHEET D-1? THERE DOES NOT SEEM TO BE ANY | | BENCHES OR GARBAGE CAN PROVIDED ON THE RESTAURANT | | PARCEL. | | | | | | LANDSCAPE (SHEETS L-1 AND L-2) COMMENTS: | | | | 1.) THE WALLS OF THE DUMPSTER ENCLOSURE SHALL BE FULLY | | LANDSCAPED WITH SHRUBS AND HEDGES PLANTED AT 2 FT. | | INTERVALS. [ZLDR S.94-315] [5/18/18 PPRC COMMENT NOT | | ADDRESSED] | | | | 2.) SHOW ALL LANDSCAPE BUFFERS THAT HAD PREVIOUSLY BEEN | | APPROVED FOR THE CPD. THIS INFORMATION IS MISSING FROM | | THE CURRENT SUBMITTAL. [5/18/18 PPRC COMMENT NOT | | ADDRESSED] | | | | 3.) ADDITIONAL COMMENTS TO BE PROVIDED BY THE CITY'S | | LANDSCAPE PLANNER. | | | | | | ARCHITECTURAL PLANS (FLOOR PLAN AND ELEVATIONS): | | | | 1.) APPLICANT HAD NOTED THAT MECHANICAL EQUIPMENT, SUCH | | AS THE A/C UNIT, WILL BE LOCATED ON THE ROOFTOP OF THE | | PROPOSED RESTAURANT BUILDING; HOWEVER, IT IS NOT CLEAR | | TO HOW THE MECHANICAL EQUIPMENT WILL BE SCREENED FROM | | PUBLIC VIEW. PLEASE DEMONSTRATE HOW THE MECHANICAL | | EQUIPMENT WILL BE SCREENED. AT MINIMUM, THERE SHOULD BE | | A NOTE IN THE PLANS THAT ALL MECHANICAL EQUIPMENT WILL | | BE SCREENED FROM VIEW BY THE BUILDING PARAPET OR WALL. | | | | PHOTOMETRICS: | | | | 1.) LOCATION OF LIGHT FIXTURES SHALL BE PROVIDED ON ALL | | PLANS FOR CONSISTENCY AND TO ENSURE THAT THE FIXTURES | | ARE NOT BE IN CONFLICT WITH EXISTING/PROPOSED SITE | | ELEMENTS. [5/18/18 PPRC COMMENT NOT ADDRESSED] | | | | | | INSTRUCTIONS FOR RESUBMITTAL: | | | | * PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | WRITTEN FORMAT. | | | | * WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF | | FIFTEEN (15) PAPER COPIES, ONE (1) REDUCED COPY IN 8.5 | | INCHES X 11 INCHES AND ONE (1) SET IN 11 INCHES X 17 | | INCHES, AND AN ELECTRONIC COPY OF ALL PLANS. PLEASE | | NOTE THAT CHANGES ON THE RESUBMITTED PLANS MAY RESULT | | IN ADDITIONAL COMMENTS. | | | | * PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE | | WILL BE 20 PERCENT ($600) OF THE ORIGINAL APPLICATION | | FEE. [NOTE: THE $600 RESUBMITTAL FEE WILL APPLY TO THE | | NEXT RESUBMITTAL] | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
05-03-2018 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
05-03-2018 |
Time |
|
Rev Time |
|
Received By |
llouie |
Date |
05-03-2018 |
Time |
|
Sent To |
|
|
Notes |
2018-05-03 15:36:59 | GENERAL COMMENTS: | | | | 1.) PLEASE CORRECT COVER SHEET (SHEET C-1) TO REFERENCE | | THE DEL TACO (NOT EXTRA SPACE STORAGE). | | | | | | MASTER DEVELOPMENT PLAN (SHEET MP-1) COMMENTS: | | | | 1.) CONCURRENCY SUMMARY TABLE SHALL REFLECT THE LATEST | | CHANGES APPROVED BY THE TPS LETTER ISSUED ON APRIL 4, | | 2018, BY THE PALM BEACH COUNTY DEPARTMENT OF PUBLIC | | WORKS AND ENGINEERING - TRAFFIC DIVISION. (I.E. | | INFORMATION ON THE RESTAURANT BUILDING SQUARE FOOTAGE, | | NUMBER OF ROOMS FOR THE HOTEL, ETC.) | | | | 2.) PARCELS #2 AND #3 (TRACTS #2 AND #3) IN THE MASTER | | DEVELOPMENT PLAN SHALL ALSO REFLECT THE LATEST BUILDING | | SQUARE FOOTAGE/# OF ROOMS APPROVED BY THE TPS LETTER | | ISSUED ON APRIL 4, 2018. | | | | 3.) PLEASE ADDRESS THE FOLLOWING INFORMATION IN THE | | CURRENCY SUMMARY TABLE: WHAT IS THE MEANING OF THE | | ASTERISK FOR THE FAST FOOD RESTAURANT IN THE FAR | | CALCULATIONS FOR THE OVERALL SITE?; ELIMINATE THE | | INFORMATION FOR THE WAWA CONVENIENCE STORE IN THE | | FOOTNOTE (*) TO SIMPLIFY/CLARIFY THE INFORMATION | | PROVIDED IN THE TABLE (I.E. WAWA SITE IS ALREADY | | DEVELOPED AND THE NOTE IS NO LONGER RELEVANT; THE HOTEL | | PARCEL IS THE ONLY PARCEL YET TO BE DEVELOPED AND | | SHOULD BE REFERENCED IN THE FOOTNOTE.). | | | | 4.) CONSIDER ELIMINATING FOOTNOTES ** FROM THE LAND USE | | AND ZONING INFORMATION TABLES FOR TRACTS #1 AND #4 IN | | ORDER TO SIMPLIFY THE DATA IN THE TABLE. THE WAWA GAS | | STATION AND CONVENIENCE STORE AND EXTRA SPACE STORAGE | | FACILITY PARCELS HAVE ALREADY BEEN APPROVED AND HAVE | | GONE THROUGH NUMEROUS AMENDMENTS. | | | | 5.) THERE IS NO REFERENCE FOR THE ** PROVIDED IN THE | | LAND USE AND ZONING INFORMATION FOR TRACT #2. THE ** | | REFERENCE SHOULD BE ELIMINATED IF THERE IS NO NOTE. | | | | 6.) THE HEADER WITHIN THE PLAN SHOULD REFERENCE DEL | | TACO (NOT EXTRA SPACE STORAGE). PLEASE ADDRESS. | | | | | | SITE PLAN COMMENTS: | | | | 1.) PURSUANT TO ZLDR S.94-207, A PLANNED DEVELOPMENT | | (PD) MUST EXHIBIT INNOVATIVE LAND PLANNING AND | | DEVELOPMENT TECHNIQUES. BASED ON STAFF'S REVIEW OF THE | | PROJECT, THE SITE PLAN SEEMS TO LACK THIS INNOVATION | | THAT WOULD CREATE FOR A MORE DESIRABLE AND ATTRACTIVE | | DEVELOPMENT. THE APPLICANT MAY WISH TO ILLUSTRATE THIS | | INNOVATION BY CREATING A PEDESTRIAN CONNECTION FROM | | BELVEDERE ROAD TO THE BUILDING (I.E. A FOOT BRIDGE OVER | | THE DETENTION POND TO THE ENTRANCE OF THE PROPOSED FAST | | FOOD RESTAURANT, ETC.). | | | | 2.) OUTDOOR SEATING SHOWN IN THE PLAN. WHAT IS THE | | CUMULATIVE SEAT COUNT (MAX.) FOR THE RESTAURANT (INSIDE | | AND OUTSIDE)? PARKING CALCULATIONS WILL NEED TO BE | | ADJUSTED IF OUTDOOR SEATING IS PROVIDED. ALSO, SHOW THE | | PARKING CALCULATIONS BASED ON THE MAXIMUM NUMBER OF | | SEATS (INDOOR AND OUTDOOR) IN THE PARKING TABLE. | | | | 3.) BASED ON THE CURRENT PARKING TABULATION PROVIDED | | FOR THE PROJECT, A MINIMUM OF TWO (2) HANDICAP PARKING | | SPACES ARE REQUIRED. HOWEVER, ONLY ONE (1) HANDICAP | | PARKING HAS BEEN PROVIDED FOR THE PROJECT. PLEASE | | ADDRESS IN THE PLAN. [ZLDR S.94-485(O)] | | | | 4.) BICYCLE RACK SHALL BE LOCATED NEAR THE ENTRANCE OF | | THE BUILDING AS PRACTICABLE. [ZLDR S.94-485(Q)] | | | | 5.) WILL THERE BE A BARRIER (DECORATIVE) BETWEEN THE | | VEHICULAR USE AREA AND THE OUTDOOR SEATING AREA? IF | | NOT, THE APPLICANT MAY WANT TO PROVIDE A BARRIER FOR | | ADDED SAFETY. | | | | 6.) CONSIDER CREATING A TEXTURED SURFACE AT THE | | PEDESTRIAN CROSSWALKS TO ENCOURAGE TRAFFIC CALMING. | | | | 7.) PLEASE DIMENSION THE DRIVE AISLES LOCATED NORTH AND | | SOUTH OF THE PROPOSED BUILDING. | | | | 8.) PLEASE DIMENSION OUT THE PEDESTRIAN WALKWAY AND | | SIDEWALKS. A MINIMUM OF 5 FT. CLEAR IS REQUIRED. | | | | 9.) IDENTIFY THE LOCATION OF ANY MECHANICAL EQUIPMENT | | (I.E. A/C UNITS, GENERATORS, ETC.). MECHANICAL | | EQUIPMENT SHALL NOT PROJECT MORE THAN 4 FT. INTO A | | REQUIRED SETBACK AND SHALL BE SCREEN FROM PUBLIC VIEW. | | [ZLDR S.94-305(B)(4)] | | | | 10.) A DETAIL OF THE DUMPSTER ENCLOSURE IS REQUIRED. | | PLEASE PROVIDE DETAIL. INCLUDE INFORMATION ON THE TYPE | | OF MATERIAL USED FOR THE ENCLOSURE, DIMENSIONS, ETC. | | [ZLDR S.94-315] | | | | 11.) WHEELS STOPS SHALL BE PROVIDED FOR THE SIX (6) | | PARKING SPACES LOCATED ALONG THE WEST SIDE OF THE | | BUILDING. | | | | 12.) PLEASE ADDRESS THE FOLLOWING IN THE LAND USE AND | | ZONING INFORMATION TABLE: REFERENCE TRACT #2 (NOT TRACT | | #4); SITE ADDRESS IS 1510 BELVEDERE ROAD (NOT 1520 | | BELVEDERE ROAD); PCN IS INCORRECT FOR THE PROJECT SITE; | | THE PROPOSED USE IS A FAST FOOD RESTAURANT W/DRIVE | | THRU; PROPOSED FAR TRACT #2 ONLY AND THE OVERALL SITE | | IS INCONSISTENT WITH THE MASTER DEVELOPMENT PLAN (SHEET | | MP-1). PLEASE CHECK CALCULATIONS AND CORRECT; CORRECT | | THE BUILDING SQUARE FOOTAGE IN THE PARKING REQUIREMENTS | | SECTION OF THE TABLE. | | | | 13.) PLEASE CORRECT THE BUFFER WAIVER NOTE TO REFLECT | | THE CURRENT PROJECT (NOT TRACT #4). | | | | | | LANDSCAPE (SHEETS L-1 AND L-2) COMMENTS: | | | | 1.) THE WALLS OF THE DUMPSTER ENCLOSURE SHALL BE FULLY | | LANDSCAPED WITH SHRUBS AND HEDGES PLANTED AT 2 FT. | | INTERVALS. [ZLDR S.94-315] | | | | 2.) PLEASE DIMENSION OUT ALL TERMINAL LANDSCAPE | | ISLANDS. PER THE ZLDRS, LANDSCAPE ISLANDS SHALL HAVE A | | MINIMUM WIDTH OF 8 FT. [ZLDR S.94-443(C)(3)] | | | | 3.) SHOW ALL LANDSCAPE BUFFERS THAT HAD PREVIOUSLY BEEN | | APPROVED FOR THE CPD. THIS INFORMATION IS MISSING FROM | | THE CURRENT SUBMITTAL. | | | | 4.) ADDITIONAL COMMENTS TO BE PROVIDED BY THE CITY'S | | LANDSCAPE PLANNER. | | | | | | ARCHITECTURAL PLANS (FLOOR PLAN AND ELEVATIONS): | | | | 1.) THE SHEET WITH THE ARCHITECTURAL ELEVATIONS IS NOT | | CLEAR AND DIFFICULT TO READ. PLEASE PROVIDE PLANS THAT | | ARE CLEARLY LEGIBLE. | | | | 2.) ELEVATIONS DO NOT MATCH THE ORIENTATION OF THE | | BUILDING PROVIDED IN THE SITE PLAN (SHEET C-5). PLEASE | | CORRECT. | | | | 3.) ELEVATIONS SHOW AWNINGS ATTACHED TO THE BUILDING. | | AWNINGS SHALL NOT PROJECT MORE THAN 4 FT. INTO ANY | | SETBACK. PLEASE DIMENSION THE PROJECTION OF THE AWNING | | FROM THE BUILDING TO ILLUSTRATE COMPLIANCE. [ZLDR | | S.94-305(B)(5)] | | | | 4.) ALL ARCHITECTURAL PLANS SHALL BE SIGNED, DATED AND | | SEALED BY A FLORIDA REGISTERED ARCHITECT. | | | | | | PHOTOMETRICS: | | | | 1.) PHOTOMETRIC PLAN NOT PROVIDED WITH THE PLANS | | PACKET. PLEASE PROVIDE. | | | | 2.) LOCATION OF LIGHT FIXTURES SHALL BE PROVIDED ON ALL | | PLANS FOR CONSISTENCY AND TO ENSURE THAT THE FIXTURES | | ARE NOT BE IN CONFLICT WITH EXISTING/PROPOSED SITE | | ELEMENTS. | | | | | | INSTRUCTIONS FOR RESUBMITTAL: | | | | * PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | WRITTEN FORMAT. | | | | * WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF | | FIFTEEN (15) PAPER COPIES, ONE (1) REDUCED COPY IN 8.5 | | INCHES X 11 INCHES AND ONE (1) SET IN 11 INCHES X 17 | | INCHES, AND AN ELECTRONIC COPY OF ALL PLANS. PLEASE | | NOTE THAT CHANGES ON THE RESUBMITTED PLANS MAY RESULT | | IN ADDITIONAL COMMENTS. | | | | * PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE | | WILL BE 20 PERCENT OF THE ORIGINAL APPLICATION FEE. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. |
|
|
|