2001-01-08 00:00:00 | SHT.P-400-DETAIL#13-OUTLET TEE ON GREASE |
| TRAP SHALL EXTEND TO WITHIN 8"OF BOTTOM |
| PER WPB UTILITIES REQS.INLETAND OUTLET |
| ARE REVERSED ON DETAIL. |
| |
| SHT.P-100-GAS PIPING SHOWN UNDER SLAB. |
| PIPING CANNOT BE INSTALLED UNDER SLAB |
| PER SGC SEC.308.3. |
| |
| SHT.P-3.02-SIZE ALL SECTIONS OF THE |
| SANITARY RISER PER COUNTYWIDE AMENDMENTS |
| TO SPC SEC.104.2.1. |
| |
| HOSE BIBB'S SHALL BE VALVED PER SPC SEC. |
| 610.3.1. |
| |
| CIVIL PLANS AND PLBG.DWGS.SHOW DOMESTIC |
| WATER SERVICE AS 4"AND SHT.P-500 NOTES |
| 3".CLARIFY. |
| |
| SHT.001-NOTE #3 STATES SANITARY PIPING |
| SHALL HAVE A 10% SLOPE.COMPLY W/SPC |
| TABLE 714.1. |
| |
| PLANS SHOW A 6" BACKFLOW PREVENTER W/A |
| 3" METER.CLARIFY. |
| |
| PLANS FOR SWIMMING POOL SHALL BE |
| APPROVED BY HEALTH DEPT.PER COUNTYWIDE |
| AMENDMENTS TO SPC SEC.101.4.7. |
| |
| INDICATE WATER SOURCE FOR IRRIGATION- |
| IF FROM A WELL OR OTHER ARTIFICIAL |
| SOURCE A WATER USE PERMIT IS REQD.PER |
| F.S.373.219. |
| |
| LOCATION OF WATER LINES ON CIVIL DWGS. |
| DON'T CORRELATE W/PLBG.PLANS.CLARIFY. |
| |
| FIXTURE DRAINS AND BRANCH DRAINS ON |
| SOVENT SYSTEM SHALL COMPLY W/ASSE |
| STANDARD #1043 SEC.3.2(E).(SEE BACK TO |
| BACK LAVS.) |
| |
| NOTE:THE SANITARY FACILITIES ON THE ROOF |
| ARE IN COMPLIANCE FOR THE OCCUPANT LOAD |
| OF THE POOL AND SPA ONLY!APPROVAL MUST |
| BE OBTAINED FROM THE HEALTH DEPT.PRIOR |
| TO APPROVAL FROM THIS DEPT.ANY OTHER |
| USE SUCH AS WEDDINGS,PARTIES,ETC, |
| CONSTITUTES A VIOLATION OF THE STD. |
| PLUMBING CODE SEC.407.1.3 FOR NUMBER |
| OF MINIMUM REQUIRED SANITARY FACILITIES. |
| |
| **************ADDENDUM****************** |
| SECONDARY DRAINAGE SYSTEM FOR ROOF SHALL |
| COMPLY W/SPC SEC.1109.2,1109.3,AND |
| APPENDIX"A".(THE OVERFLOW SYSTEM IS |
| INADEQUATE AS DESIGNED.THE 4" OVERFLOW |
| DRAINS WILL NOT CARRY THE ADJUSTED SQ. |
| FOOTAGE.) |
| |
| CLEARLY INDICATE SQ.FOOT AREA OF THE |
| ROOF AND THE SLOPE OF THE STORM DRAINAGE |
| PIPING ABOVE AND BELOW GROUND.COMPLY W/ |
| TABLES 1108.1 &1108.2 OF SPC. |