Notes
Date Text
2001-01-08 00:00:00SHT.A001-APPLICABLE CODES-THE 1994 EDIT.
 OF THE STANDARD PLBG.CODE W/PALM BEACH
 COUNTY AMENDMENTS IS THE ADOPTED
 STANDARD.REVISE NOTE.
  
 THE MAXIMUM CAPACITY OF GREASE INTER-
 CEPTOR SHALL BE 1250 GALS.PER STATE OF
 FLA.HEALTH DEPT.REQS.CHAPT.64E-6.013(5).
  
 SIZE AND CAPACITY OF INTERCEPTORS SHALL
 BE APPROVED BY CITY OF WPB REGIONAL
 WASTEWATER TREATMENT PLANT.CONTACT
 RODNEY COMPO AT (561)835-7423.
  
 SUBMIT DETAIL OF OIL/SAND INTERCEPTOR.
 SPC1004.2.
  
 SHTS.P1.01,1.02,SHOWS 6" INLET TO OIL/
 SAND INTERCEPTOR AND 4" OUTLET.SPC 709.1
  
 SUBMIT ISOMETRIC DRAWINGS FOR ENTIRE
 SCOPE OF WORK TO BE DONE AT THIS TIME.
 SIZE ALL LINES AND INDICATE SLOPE OF
 PIPE.COUNTYWIDE AMENDMENTS TO SPC SEC.
 104.2.1.
  
 SUBMIT ISOMETRIC FOR STORM DRAINAGE
 SYSTEM.SHOW SQUARE FOOT AREA DRAINED BY
 EACH ROOF DRAIN AND SUPPLY CALCULATIONS
 FOR SECONDARY DRAINAGE FOR ROOF.COMPLY
 W/SBC SEC.1517.6.4.1-1517.6.4.3.
 SPC 1108.1,1108.2.,APPENDIX "A",TABLE
 A101.2.INDICATE SLOPE OF PIPE.
  
 INDICATE WATER SOURCE FOR IRRIGATION
 SYSTEM.IF FROM A NON-POTABLE SOURCE A
 WATER USE PERMIT FROM SFWMD MAY BE REQD.
 PER F.S.373.219.
  
 NOTE:PLUMBING PLAN REVIEW IS FOR SHELL
 ONLY.DOES NOT INCLUDE REVIEW FOR LIVING
 UNITS,COMMON AREAS,OR REQS.FOR HANDICAP
 ACCESSIBILITY.
  
 THIS IS FOUNDATION ONLY PERMIT.NO
 PLUMBING WORK OF ANY NATURE IS PERMITTED
 3/8/00.TLARGE.


Account Summary | Usage Policy | Privacy Policy