Date |
Text |
2001-01-08 00:00:00 | SHT.P-1-THE WATER SERVICE TO THE CABANA |
| DOESN'T APPEAR TO BE PROTECTED AGAINST |
| BACKFLOW.COMPLY W/SPC SEC.606.1. |
| |
| DRINKING FOUNTAIN AT CABANA SHALL |
| COMPLY W/FACBC SEC.4.1.3(10)(A). |
| |
| SHT.P-1.-SHOW DIMENSIONS OF TOILET ROOMS |
| COMPLY W/FACBC SEC.4.16.2.AND FIG.28. |
| |
| SUBMIT NUMBER OF PERSONS THAT WILL BE |
| UTILIZING THE CABANA AT ANY ONE TIME. |
| COMPLY W/TABLE 407 OF SPC. |
| |
| SHT.P-2-CONDENSATE LINES ARE SHOWN AS |
| 2" AND 1 1/4" CLARIFY. |
| |
| SHT.P-2-SUBMIT A SANITARY ISOMETRIC THAT |
| IS LEGIBLE AND CLEARLY REFLECTS THE |
| SCOPE OF THE INSTALLATION PER COUNTYWIDE |
| AMENDMENTS TO SPC SEC.104.2.1. |
| |
| ENERGY CALCS.NOTE EWH AS 60 GALS.AND SHT |
| P-1 NOTES 30 GAL.CLARIFY.FEC SEC.103.2. |
| (SEE SHT.P-7) |
| |
| CONDENSATE DRAINS ON MULTIPLE STORY |
| BUILDINGS SHALL BE VENTED WHERE 2 OR |
| MORE UNITS ARE CONNECTED TO COMMON RISER |
| PER COUNTYWIDE AMENDMENTS SEC.5. |
| |
| SUBMIT CONDENSATE RISER FOR REVIEW PER |
| COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1 |
| |
| SUBMIT IRRIGATION PLANS IF APPLICABLE & |
| INDICATE WATER SUPPLY SOURCE FOR SYSTEM. |
| A WATER USE PERMIT FROM SFWMD MAY BE |
| REQD.PER F.S.373.219,373.62. |
| |
| CIVIL DRAWINGS SHALL BE SIGNED AND |
| SEALED PER COUNTYWIDE AMENDMENTS TO SPC |
| SEC.104.2.3.,F.S.471.025. |
| |
| NOTE:A SEPARATE PERMIT SHALL BE REQD.FOR |
| THE POOL,FOUNTAIN,CABANA . |