2001-01-08 00:00:00SHT.P-1-THE WATER SERVICE TO THE CABANA
 DOESN'T APPEAR TO BE PROTECTED AGAINST
 BACKFLOW.COMPLY W/SPC SEC.606.1.
  
 DRINKING FOUNTAIN AT CABANA SHALL
 COMPLY W/FACBC SEC.4.1.3(10)(A).
  
 SHT.P-1.-SHOW DIMENSIONS OF TOILET ROOMS
 COMPLY W/FACBC SEC.4.16.2.AND FIG.28.
  
 SUBMIT NUMBER OF PERSONS THAT WILL BE
 UTILIZING THE CABANA AT ANY ONE TIME.
 COMPLY W/TABLE 407 OF SPC.
  
 SHT.P-2-CONDENSATE LINES ARE SHOWN AS
 2" AND 1 1/4" CLARIFY.
  
 SHT.P-2-SUBMIT A SANITARY ISOMETRIC THAT
 IS LEGIBLE AND CLEARLY REFLECTS THE
 SCOPE OF THE INSTALLATION PER COUNTYWIDE
 AMENDMENTS TO SPC SEC.104.2.1.
  
 ENERGY CALCS.NOTE EWH AS 60 GALS.AND SHT
 P-1 NOTES 30 GAL.CLARIFY.FEC SEC.103.2.
 (SEE SHT.P-7)
  
 CONDENSATE DRAINS ON MULTIPLE STORY
 BUILDINGS SHALL BE VENTED WHERE 2 OR
 MORE UNITS ARE CONNECTED TO COMMON RISER
 PER COUNTYWIDE AMENDMENTS SEC.5.
  
 SUBMIT CONDENSATE RISER FOR REVIEW PER
 COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1
  
 SUBMIT IRRIGATION PLANS IF APPLICABLE &
 INDICATE WATER SUPPLY SOURCE FOR SYSTEM.
 A WATER USE PERMIT FROM SFWMD MAY BE
 REQD.PER F.S.373.219,373.62.
  
 CIVIL DRAWINGS SHALL BE SIGNED AND
 SEALED PER COUNTYWIDE AMENDMENTS TO SPC
 SEC.104.2.3.,F.S.471.025.
  
 NOTE:A SEPARATE PERMIT SHALL BE REQD.FOR
 THE POOL,FOUNTAIN,CABANA .