2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-REVISE THE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE FORM. THE
 MEAN ROOF HEIGHT IS TAKEN FROM GRADE,
 NOT FROM FINISH FLOOR, TO THE AVERAGE
 POINT OF THE HIGHEST ROOF. THEREFORE,
 THE MEAN ROOF HEIGHT FOR THIS BUILDING
 IS PLUS OR MINUS 19'-4".
 NOTE: REVISE DRAWING #1 AS WELL.
 2-PROVIDE COPIES OF THE APPROVED DRAWING
 FOR ENTRY DOORS PRODUCT APPROVAL.
 3-PROVIDE SOIL TEST REPORT.
 NOTE: SEE SECTION 1804.2.7.2 OF CITY
 AMENDMENTS FOR MINIMUN REQUIREMENTS.
 -PROVIDE TWO COPIES OF SOIL TEST REPORT
 SIGNED, SEALED AND DATED. (EMBOSSED
 SEAL).
 4-STORM PANELS:
 -UPDATE INSTALLATION SCHEDULE AND KEY
 PLAN TO MATCH ARCHITECT'S FLOOR PLAN
 AND EXTERIOR ELEVATIONS.
 -REVISE PANELS #2 AND #16. PANELS THAT
 ARE LONGER 9'-4" SHALL BE BOLTED. SEE
 NOTE #7 ON GENERAL NOTES OF PRODUCT
 APPROVAL, SHEET 1 OF 8.
 -SPECIFY ANCHOR SPACING FOR PANELS THAT
 ARE LONGER THAN 8'-0".