Plan Review Notes
Plan Review Notes For Permit 99111320
Permit Number 99111320
Review Stop R
Sequence Number 1
Notes
Date Text
2001-01-08 00:00:00THE PLANS NEEDS TO HAVE PERSONAL
 SIGNATURE OVER THE RAISE SEAL OF THE
 ARCHITECT.
  
 THE GUEST SUITE WINDOWS ARE REQUIRED TO
 PROVIDE THE EGRESS REQUIREMENTS STATED
 IN SECTION 1005.4.4 SBC 1997. NOTE PGT
 WINDOW SIZE OF 24SH DOES NOT MEET THE
 CODE REQUIREMENT.
  
 THE US TRUSS LAYOUT PLAN ILLUSTRATES A
 2 STORY STRUCTURE AND THE ARCHITECT
 PALNS SPECIFY A ONE STORY STRUCTURE.
  
 THE FRONT DOOR IS REQUIRED TO PROVIDE A
 MINIUM 32" CLEAR OPENING WHEN ONE LEAF
 IS OPEN.
  
 PROVIDE PRODUCT APPROVAL FOR THE EXTERIO
 SWING DOORS.
  
 THE DESIGN COMPLIANCE FORM SPECIFYS THAT
 THE STRUCTURE WAS DESIGNED ACCORDING TO
 THE INVALID CODE EDITION, SBC 1994. NOTE
 THAT THE CURRENT CODE EDITION IS THE
 1997 SBC. ATTACHED IS A COPY OF THE
 UPDATED DESIGN COMPLIANCE FORM.
  
 CLARIFY THE HEIGHT AND WIDTH DEMINSION
 FOR THE F1 FOOTER.