2001-01-08 00:00:00 | ALL PUBLIC AND COMMON USE TOILET ROOMS |
| SHALL COMPLY W/FACBC SEC.4.1.3(11) & |
| 4.22. |
| |
| THE DRINKING FOUNTAIN SHALL COMPLY W/ |
| FACBC SEC.4.1.3.(10)(A).(SEE ATTACHED |
| FLA.HANDICAP ACCESSIBILITY CODE SECTION |
| AND COMPLY TO EXTENT REQUIRED BY CODE.) |
| |
| THE SINK SHALL COMPLY W/FACBC SEC.4.24.1 |
| THRU 4.24.7. |
| |
| SUBMIT SQUARE FOOTAGE OF SPACE AND |
| OCCUPANT LOAD.COMPLY W/SPC TABLE 407 FOR |
| NUMBER AND TYPE OF REQD.PLUMBING |
| FIXTURES. |
| |
| THERE SHALL BE AN UNOBSTRUCTED TURNING |
| SPACE COMPLYING W/FACBC 4.2.3 PROVIDED |
| WITHIN AN ACCESSIBLE TOILET ROOM. |
| SPECIAL NOTE:IF THE NOTED CLEAR SPACE |
| AREA OF 10" BELOW THE HANDICAPPED WATER |
| CLOSET IS NOT AVAILABLE AS SHOWN ON THE |
| SIGNED AND SEALED ADDENDUM FROM THE |
| DESIGN PROFESSIONAL OF RECORD THE TOILET |
| ROOM SHALL COMPLY FULLY W/THE REQS.OF |
| FACBC SEC.4.2.3.AND 4.22.3. |
| |
| SUBMIT A WATER RISER DIAGRAM THAT |
| CLEARLY REFLECTS THE ENTIRE SCOPE OF |
| PLUMBING WORK.(THE SUBMITTED WATER RISER |
| ONLY SHOWS TWO TOILET ROOMS,NOT THREE AS |
| SHOWN ON THE PLANS)PER COUNTYWIDE AMEND- |
| MENTS TO STD.PLBG.CODE SEC.104.2.1.WATER |
| SUPPLY CONTROL SHALL COMPLY W/SPC SEC. |
| 610.4.1,610.4.2. |