2001-01-08 00:00:00SHT.PD-P3.01-MAX.20,700 SQ.FT.PERMITTED
 ON 10" RWL AT 1/8" PER FT.(SEE COLS.B-2
 C-2,C-8.)COMPLY W/SPC 1108.2.
  
 SHT.PD-P3.01-PLANS SHOW 15"RWL DRAINING
 INTO 10" LINE.SPC SEC.307.5,709.1.SEE
 COL.C-5.2.
  
 SIZE THE UNDERGROUND HORIZONTAL SECTIONS
 FOR ALL THE STORM RISERS.COMPLY W/SPC
 SEC.1108.2 AND TABLE 1108.2.
  
 CLEARLY SHOW PROVISIONS FOR OVERFLOW
 DRAINAGE PER SPC 1109.1-1109.3.SUBMIT
 DETAILS OF OVERFLOW OPENINGS.
  
 SUBMIT CALCULATIONS FOR INCLUSION OF
 1/2 THE AREA OF ANY VERTICAL WALL WHICH
 DIVERTS RAIN WATER TO THE ROOF.SPC SEC.
 1108.3.