2001-01-08 00:00:00DESIGN OF GREASE TRAP SHALL COMPLY W/
 FLA.ADMIN.CODE RULE 64E-6.013(5).
 A.)DELETE TEE FITTING FROM INLET TO
 GREASE TRAP.INLET INVERT SHALL DISCHARGE
 A MIN.OF 2 1/2" ABOVE LIQUID LEVEL LINE.
  
 B.)THE OUTLET SHALL EXTEND TO WITHIN 8"
 OF THE BOTTOM OF THE TANK.
  
 C.)GREASE INTERCEPTORS SHALL BE EQUAL
 CAPACITY WHEN INSTALLED IN SERIES.
  
 D.)APPROVAL FROM CITY OF WEST PALM BEACH
 UTILITIES IS REQUIRED FOR THE CHANGES TO
 THE GREASE INTERCEPTOR.CONTACT RODNEY
 COMPO AT(561)835-7423 FOR INFORMATION.
  
 IF YOU HAVE ANY QUESTIONS I CAN BE
 REACHED AT (561)659-8096,EXT.8377.
 TIMOTHY K.LARGE, PLANS EXAMINER.