Plan Review Notes For Permit 99090087 |
Permit Number |
99090087 |
|
Review Stop |
R |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2001-01-08 00:00:00 | APPROVED WITH PROVISO: | | 1-PLEASE REVISE ALL ORIGINAL DRAWINGS | | SHOWING ALL CORRECTIONS/CLARIFICATIONS | | AS REQUESTED ON PLANS. | | 2-PROVIDE 32" MINIMUM CLEAR OPENING AT | | ENTRY DOOR. TABLE 1004 SBC 1997. | | 3-REVISE DESIGN CERTIFICATION FOR WIND | | LOAD COMPLIANCE FORM. MEAN ROOF HEIGHT | | IS 23'-6" PLUS O MINUS. SEE COMMENTS | | ON PLANS. | | 4-PROVIDE ATTIC ACCESSS AT ENTRY TOWER | | AND AT GUEST SUITE/GOLFCART AREA AS | | PER SEC. 2309.6 SBC 1997. | | 5-PROVIDE SIZES OF CEILING FANS AS PER | | TABLE 6-6 OF FLORIDA ENERGY CODE, 1997 | | 6-CLARIFY IF FIXED WINDOW AT GRAND ROOM | | HAS TRUE MULLIONS OR NOT IN ORDER TO | | VERIFY ACTUAL SIZE OF WINDOW. | | 7-STORM PANELS: PROVIDE A COMPLETE | | INSTALLATION SCHEDULE AS PER CITY | | SAMPLE AND KEY PLAN. | | 8-PROVIDE TWO COPIES OF ENGINEERED ROOF | | TRUSSES SIGNED AND SEALED AND REVIEWED | | BY DESIGNER OF RECORD. | | 9-PROVIDE PRODUCT APPROVAL FOR WINDOW AT | | DINING AREA. |
|