Plan Review Notes
Plan Review Notes For Permit 99081124
Permit Number 99081124
Review Stop P
Sequence Number 2
Notes
Date Text
2001-01-08 00:00:00CLEAR FLOOR SPACE REQD.FOR URINAL PER
 FACBC SEC.4.18.3.
  
 SIZE OF HANDICAP STALL SHALL COMPLY W/
 4.17.3(SEE NEW CONSTRUCTION).
  
 SHOW SQ.FOOT AREA DRAINED BY EACH ROOF
 DRAIN AND SUPPLY DETAILS FOR SECONDARY
 DRAINAGE PER SPC SEC.1109.
  
 SHUT-OFF VALVE AND BACKFLOW PREVENTER
 REQD.ON WATER SERVICE PER SPC SEC.606 &
 610.1.
  
 SIZE ALL SECTIONS OF THE SANITARY RISER.
 COMPLY W/TABLES 714.1,714.2,920.2 FOR
 SIZING REQS.
  
 PRIVACY SCREEN REQD.BETWEEN URINAL AND
 WATER CLOSET.SPC SEC.404.3.