Plan Review Notes For Permit 99080073 |
Permit Number |
99080073 |
|
Review Stop |
E |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2001-01-08 00:00:00 | ***************PROVISO****************** | | | | 1) NOTE:AS PER 1996 NFPA-72 2-2.1.1.1 | | SMOKE DETECTORS ARE REQ`D INSIDE AND | | OUTSIDE BEDROOMS ON NEW HOMES. | | 2) NOTE;AS PER ART;210-8-A-6 ALL OUTLETS | | SERVING KITCHEN COUNTER SPACE ARE TO BE | | GFI/GFI PROTECTED. | | 3) NOTE;OUTLET AS PER 210-52 REQ`D IN | | MASTER BEDROOM. | | 4) NOTE;GROUNDING ELECTRODE CONDUCTOR | | TO GOT TO BLDG.STEEL ALSO AS PER ART; | | 250-81 | | 5) NOTE;NEED TO SUBMIT AIC RATING OF | | ALL EQUIPMENT AND BREAKERS.AS PER ARTS; | | 110-9 AND 215-5 | | | | PLEASE DO ALL THE ABOVE AND HAVE | | SUBMITTED AND APPROVED BEFORE ELECTRICAL | | ROUGH INSPECTION. |
|