Plan Review Notes
Plan Review Notes For Permit 99080036
Permit Number 99080036
Review Stop P
Sequence Number 4
Notes
Date Text
2001-01-08 00:00:00SHOWERS SHALL BE PROVIDED PER SPC TABLE
 407.(SEE REQS.FOR DORMITORIES.)
  
 CLEARLY SHOW ON PLANS THAT FLOORS AND
 WALLS IN COMMON AREA BATHROOMS AND
 TOILET ROOMS COMPLY W/SBC SEC.1204.2.
  
 SIZE REQUIREMENT AND DESIGN OF GREASE
 TRAP SHALL COMPLY W/HEALTH DEPT.REQS.
 AND CITY OF WEST PALM BEACH UTILITIES.
 CONTACT RODNEY COMPO AT CITY OF WPB
 REGIONAL WASTEWATER TREATMENT FACILITY.
 SEEFLA.ADMIN.CODE SEC.64E-6.013(5)(A).
  
 CLEARLY SHOW ON PLAN THAT GREASE TRAP
 WILL NOT BE LOCATED WITHIN ANGLE OF
 REPOSE.
  
 MINIMUM INLET AND OUTLET TO GREASE TRAP
 SHALL BE 4" AND INLET SHALL DISCHARGE A
 MIN.OF 2 1/2" ABOVE LIQUID LEVEL LINE.