Plan Review Notes For Permit 99070638 |
Permit Number |
99070638 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2001-01-08 00:00:00 | CLEARLY SHOW DIMENSIONS OF HANDICAP | | STALLS.COMPLY W/F.A.C.B.C.FOR MIN.CLEAR- | | ANCES FOR FIXTURES,HEIGHT REQ'S.,ETC. | | SEE SECS.4.17.3.(EXCEPTION:NEW | | CONSTRUCTION),4.16.3, 4.18.2, 4.19.2, | | | | WATER CLOSET IN WOMEN'S RESTROOM SHALL | | BE LOCATED IN CORNER,DIAGONAL TO THE | | DOOR PER F.A.C.B.C.SEC.4.17.3. | | | | WALLS AND FLOORS OF TOILET ROOMS SHALL | | COMPLY W/ STD.BLDG.CODE SEC.1204.2 | | | | INDICATE OCCUPANT LOAD (INCLUDING | | EMPLOYEES)TO ENSURE COMPLIANCE FOR MIN. | | FIXTURE REQ'S PER SPC TABLE 407. | | | | A DRINKING FOUNTAIN IS REQ'D.PER SPC | | TABLE 407. | | | | FLOOR DRAINS SHALL BE EQUIPPED W/TRAP | | PRIMERS PER SPC SEC.409.4.1.1. | | | | SIZE ALL VENTS ON THE SAN.RISER & NOTE | | SLOPE OF PIPE. SPC TABLES 714.1, 714.2, | | 920.2. |
|