Plan Review Notes
Plan Review Notes For Permit 99070638
Permit Number 99070638
Review Stop P
Sequence Number 1
Notes
Date Text
2001-01-08 00:00:00CLEARLY SHOW DIMENSIONS OF HANDICAP
 STALLS.COMPLY W/F.A.C.B.C.FOR MIN.CLEAR-
 ANCES FOR FIXTURES,HEIGHT REQ'S.,ETC.
 SEE SECS.4.17.3.(EXCEPTION:NEW
 CONSTRUCTION),4.16.3, 4.18.2, 4.19.2,
  
 WATER CLOSET IN WOMEN'S RESTROOM SHALL
 BE LOCATED IN CORNER,DIAGONAL TO THE
 DOOR PER F.A.C.B.C.SEC.4.17.3.
  
 WALLS AND FLOORS OF TOILET ROOMS SHALL
 COMPLY W/ STD.BLDG.CODE SEC.1204.2
  
 INDICATE OCCUPANT LOAD (INCLUDING
 EMPLOYEES)TO ENSURE COMPLIANCE FOR MIN.
 FIXTURE REQ'S PER SPC TABLE 407.
  
 A DRINKING FOUNTAIN IS REQ'D.PER SPC
 TABLE 407.
  
 FLOOR DRAINS SHALL BE EQUIPPED W/TRAP
 PRIMERS PER SPC SEC.409.4.1.1.
  
 SIZE ALL VENTS ON THE SAN.RISER & NOTE
 SLOPE OF PIPE. SPC TABLES 714.1, 714.2,
 920.2.