Plan Review Notes
Plan Review Notes For Permit 99051186
Permit Number 99051186
Review Stop P
Sequence Number 3
Notes
Date Text
2001-01-08 00:00:00SHT.A7.1-WOMEN'S R.R.-MIN.CLEARANCE FOR
 WHEELCHAIR IS 32" PER F.A.C.B.C. SEC.
 4.2.1.(SEE AREA AT ADDED H.C. STALL DOOR
 AND STALL PARTITION.)
  
 SHT.P.7-8" RWL IS DRAINING INTO 6" LINE.
 COMPLY W/SPC 307.5, TABLES 1108.1,
 108.2.
  
 SHT.P.8-SHOWER IN MEN'S ROOM NOT SHOWN
 ON RISER.SPC SEC.104.2.1.(SEE P.3,3RD.
 FLR.)
  
 SHT.P.8-(3RD.FLR.)-OVER 2 FIXTURES ON
 1/2" C.W.(SEE D.F.'S.)AMENDMENTS TO
 CODE SEC.607.7
  
 SHT.P.8-OVER 2 FIXTURES CONNECTED TO
 1/2"C.W.(SEE UPPER CAFE AREA)AMENDMENTS
 TO STANDARD PLBG.CODE SEC.607.7.(SEE
 P901,P902.)
  
 SHT.P.1-FLOOR DRAIN IN STORAGE ROOM
 EXCEEDS DISTANCE FROM VENT.COMPLY W/
 TABLE 908.1 OF SPC.