Plan Review Notes For Permit 99041194
Permit Number 99041194
Review Stop P
Sequence Number 4
Notes
Date Text
2001-01-08 00:00:00DESIGN OF GREASE INTERCEPTOR SHALL
 COMPLY W/CITY OF WPB UTILITIES REQS.
 CONTACT RODNEY COMPO AT (561)835-7423.
  
 SHT.CP-3.06.CONNECTION OF CONDENSATE TO
 STORM DRAIN SHALL BE BY INDIRECT
 CONNECTIONS PER SPC 804.3.,807.2,
  
 FLOOR DRAINS AT COMPACTOR SHALL BE A
 MAXIMUM OF 15' FROM THE VENT,NOT A MIN.
 OF 15'.COUNTYWIDE AMENDMENTS TO SPC SEC.
 908.1,FOOTNOTE #1.
  
 SUBMIT DETAIL OF GAS MANIFOLD.THE
 MANIFOLD IS LOCATED NEXT TO A
 TRANSFORMER PAD THAT WILL SERVE
 EQUIPMENT THAT MAY BE CONSIDERED A
 SOURCE OF IGNITION.SUBMIT INFO ON EQUIP.
 BEING LOCATED ON PAD.COMPLY W/NFPA 54
 SEC.1.7.
  
 SHT.CMP-3.01-VTR IS LOCATED WITHIN 10'
 OF OAI-3 .COMPLY W/SPC SEC.905.5.
  
 NOTE:EARLIER REVISIONS OF THESE PLANS
 HAVE BEEN APPROVED W/PROVISOS ON 3/21/00
 BY T.LARGE AND THE LATER REVISIONS SHALL
 BE CORRECTED PRIOR TO APPROVAL.