2001-01-08 00:00:00 | ***********UNSAT*********************** | | | | 1)NOTE: NEED LOAD CALCULATIONS AS PER | | 220-3-D-1 | | 2)NOTE: NEED TO SHOW SIZE OF EXISTING | | SERVICE TO INCLUDE SERVICE WIRE SIZE. | | 3)NOTE: NEED TO SHOW NEW PANEL SCHEDULE | | FOR ADDITION OF NEW CIRCUTS TO EXISTING | | PANEL. DINING AREA REQ`S 20 AMP BRANCH | | CIRCUTS AS PER CODE. | | 4)NOTE: ALSO AS PER 210-52D BATH REC IS | | TO ON IT`S OWN 20 AMP BRANCH CIRCUT. | | 5)NOTE: PLEASE SHOW EXISTING LOCATION | | OF REC AT REAR OF RESIDENCE AS REQ`D BY | | 210-52 E IF NO REC EXIST THEN ONE NEEDS | | TO BE ADDED TO REAR OF ADDITION. | | 6)NOTE: NEED TO HAVE SMOKE DETECTORS | | INSIDE AND OUTSIDE ALL NEW BEDROOMS | | AS REQ`D BY NFPA-72 2-2.1.1.1 1993/1996 | | EDDITION. | | | | PLEASE SUBMIT THE ABOVE INFORMATION | | FOR REVIEW AND APPROVAL. IF THERE ARE | | ANY QUESTIONS OR I CAN BE OF ANY ASST. | | PLEASE CONTACT ME AT 659-8096 EXT8372 |
|