Plan Review Notes For Permit 23061369 |
Permit Number |
23061369 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2023-07-03 16:27:00 | PETER E VALENTI | | BUILDING PLANS EXAMINER II/INSPECTOR | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | BUILDING REVIEW DENIED: | | | | 1.) FBC R 301.2.1.4.2, DUE TO THE OPEN AREA TO THE | | NORTH AND EAST OF THIS STRUCTURE, IT APPEARS THE | | SURFACE ROUGHNESS CATEGORY SELECTED "B" SHOULD BE | | CHANGED TO "C" AS PER THE DESCRIPTIONS IN THIS CODE | | SECTION. | | | | 2.) FBC B 107.2.1, PLEASE CLARIFY THE ATTACHMENT METHOD | | OF THE PANEL RACK MOUNTS TO THE ROOF FRAMING. THE | | SUBMITTED PLANS APPEAR TO SHOW DIFFERENT METHODS OF | | ATTACHMENT. AS PER PLAN SHEETS S-02 & S-03 GENERAL NOTE | | #2, SHOW THE DIMENSIONS OF LAG BOLTS AND EMBEDMENT | | DEPTH OF LAG BOLTS INTO THE TOP CHORD OF ROOF FRAMING | | MEMBERS. |
|