2023-07-07 14:04:24PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SPECIFY THE HEIGHT OF THE AWNING FRAME AND FABRIC
 ABOVE THE WALKWAY. FBC 3105.3.1.1 FABRIC AWNINGS AND
 FABRIC-COVERED FRAMES LOCATED OVER PUBLIC PROPERTY OR
 IN AREAS ACCESSIBLE TO THE GENERAL PUBLIC SHALL BE
 CONSTRUCTED SO THAT NO RIGID PART OF SUCH FABRIC
 AWNINGS OR FABRIC-COVERED FRAMES SHALL BE LESS THAN 7
 FEET 6 INCHES (2286 MM) FROM THE GRADE DIRECTLY BELOW,
 AND NO PART OF THE CLOTH DROP SHALL BE LESS THAN 7 FEET
 (2134 MM).
  
 2) SUBMIT TWO SETS OF DETAILED AWNING REMOVAL
 INSTRUCTIONS WITH PHOTOGRAPHS/DRAWINGS THAT SHOW HOW
 THIS IS DONE IN TERMS THAT A LAYMAN WILL UNDERSTAND.
 THESE INSTRUCTIONS ARE TO BE PROVIDED TO THE PROPERTY
 OWNER, OWNER'S REPRESENTATIVE OR LESSEE. FBC 107.2.1
  
 3) SUBMIT THE FLAME SPREAD CERTIFICATE FOR THE AWNING
 FABRIC. FBC 3105.3.4.1 FABRIC USED FOR AWNINGS OR
 FABRIC-COVERED FRAMES SHALL MEET THE FLAME PROPAGATION
 PERFORMANCE CRITERIA OF NFPA 701 OR HAVE A FLAME SPREAD
 INDEX NOT GREATER THAN 25 WHEN TESTED IN ACCORDANCE
 WITH ASTM E84 OR UL 723.
  
 4) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH
 OF THE REVIEW COMMENTS HAS BEEN ADDRESSED.