Plan Review Notes For Permit 23060727 |
Permit Number |
23060727 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2023-06-29 17:00:31 | PETER E VALENTI | | BUILDING PLANS EXAMINER II/INSPECTOR | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | BUILDING REVIEW DENIED: | | | | FBC R 301.2.1.4.2, DUE TO THE GOLF COURSE, THE SURFACE | | ROUGHNESS CATEGORY APPEARS TO BE CONSIDERED "D" NOT "C" | | AS SHOWN ON THE SUBMITTED DOCUMENTS. PLEASE CORRECT THE | | SUBMITTAL INFORMATION FROM SURFACE ROUGHNESS CATEGORY | | "C" TO "D" AND RECALCULATE THE WINDLOAD INFORMATION | | INCLUDING PRESSURES. |
|