2023-06-29 17:00:31PETER E VALENTI
 BUILDING PLANS EXAMINER II/INSPECTOR
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 FBC R 301.2.1.4.2, DUE TO THE GOLF COURSE, THE SURFACE
 ROUGHNESS CATEGORY APPEARS TO BE CONSIDERED "D" NOT "C"
 AS SHOWN ON THE SUBMITTED DOCUMENTS. PLEASE CORRECT THE
 SUBMITTAL INFORMATION FROM SURFACE ROUGHNESS CATEGORY
 "C" TO "D" AND RECALCULATE THE WINDLOAD INFORMATION
 INCLUDING PRESSURES.