Plan Review Notes
Plan Review Notes For Permit 23060418
Permit Number 23060418
Review Stop B
Sequence Number 4
Notes
Date Text
2023-07-25 14:16:31JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC B 107.2.1 REVISE SCOPE OF WORK ON PERMIT
 APPLICATION TO INCLUDE INCREASE VALUE FOR ROOF-TO-WALL
 MITIGATION. WORK TO BE PERFORMED BY A LICENSED
 RESIDENTIAL CONTRACTOR, LICENSED BUILDING CONTRACTOR OR
 LICENSED GENERAL CONTRACTOR. PROVIDE CONTRACTORS NAME &
 LICENSE NUMBER ON PERMIT APPLICATION.
 2. FBC EB 706.8.1 PROVIDE ROOF-TO-WALL LOAD PATH
 CONNECTION ANALYSIS SHOWING COMPLIANCE WITH WIND LOADS
 IN TABLE 706.8.1 SUBMITTED & VALIDATED BY A LICENSED
 FLORIDA DESIGN PROFESSIONAL.
 3. FBC B 107.2.1 ITEM #1 & ITEM #2 ABOVE MUST BE
 COMPLETED BEFORE ROOFING PERMIT CAN BE APPROVED.
 ALTERNATIVE; PROVIDE A DETAILED COST ESTIMATE OF THE
 EVALUATION AND INSTALLATION OF CONNECTIONS AT THE GABLE
 ENDS OR ALL CORNERS THAT WILL EXCEED 15% OF THE COST OF
 THE ROOF REPLACEMENT WHEN COMPLETED.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  


Account Summary | Usage Policy | Privacy Policy