Date |
Text |
2023-06-30 09:52:11 | REMODEL |
| REVIEWED BY ROGER MCPHERSON |
| 561-805-6716 |
| [email protected] |
| CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| AMENDMENT |
| |
| CORRECTIONS NEEDED - |
| |
| 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE |
| INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE |
| PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS AND DOORS - |
| ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED |
| APPROVED BY THE ENGINEER OF RECORD FBC WPB 107.3.4 |
| |
| 2) ACCESSIBLE RESTROOM - PLEASE SHOW THE TOILET PAPER |
| HOLDER DIMENSIONS FROM THE FACE OF THE TOILET TO THE |
| CENTER OF THE TOILET PAPER HOLDER FBC A 604.7 |
| DISPENSERS. |
| TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND |
| SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 |
| MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO |
| THE CENTERLINE OF THE DISPENSER. |
| |
| 3) ACCESSIBLE RESTROOM - PLEASE USE THE WORDS |
| "REFLECTIVE SURFACE" WHEN REFERRING TO THE DIMENSIONS |
| OF THE MIRROR FROM THE FLOOR - FBC A 603.3 MIRRORS. |
| MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL |
| BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING |
| SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH |
| FLOOR OR GROUND |
| |
| 4) ACCESSIBLE RESTROOM - PLEASE SHOW THE TOILET GRAB |
| BAR HEIGHT TO THE TOP OF THE GRIPPING SURFACE (NOT TO |
| THE CENTER OF THE BAR) - FBC A 609.4 POSITION OF GRAB |
| BARS. |
| GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, |
| 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM) |
| MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF |
| THE GRIPPING SURFACE |
| |
| 5) EXTERIOR WINDOW AND DOOR PRODUCT APPROVALS MAY BE |
| DEFERRED SUBMITTALS BY LISTING THE ITEMS TO BE DEFERRED |
| ON THE CONSTRUCTION DOCUMENTS - FBC WPB107.3.4.1 |
| |