Notes
Date Text
2023-06-30 09:52:11REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS AND DOORS -
 ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED
 APPROVED BY THE ENGINEER OF RECORD FBC WPB 107.3.4
  
 2) ACCESSIBLE RESTROOM - PLEASE SHOW THE TOILET PAPER
 HOLDER DIMENSIONS FROM THE FACE OF THE TOILET TO THE
 CENTER OF THE TOILET PAPER HOLDER FBC A 604.7
 DISPENSERS.
 TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230
 MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER.
  
 3) ACCESSIBLE RESTROOM - PLEASE USE THE WORDS
 "REFLECTIVE SURFACE" WHEN REFERRING TO THE DIMENSIONS
 OF THE MIRROR FROM THE FLOOR - FBC A 603.3 MIRRORS.
 MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND
  
 4) ACCESSIBLE RESTROOM - PLEASE SHOW THE TOILET GRAB
 BAR HEIGHT TO THE TOP OF THE GRIPPING SURFACE (NOT TO
 THE CENTER OF THE BAR) - FBC A 609.4 POSITION OF GRAB
 BARS.
 GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION,
 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM)
 MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF
 THE GRIPPING SURFACE
  
 5) EXTERIOR WINDOW AND DOOR PRODUCT APPROVALS MAY BE
 DEFERRED SUBMITTALS BY LISTING THE ITEMS TO BE DEFERRED
 ON THE CONSTRUCTION DOCUMENTS - FBC WPB107.3.4.1
  