Plan Review Notes For Permit 23051624 |
Permit Number |
23051624 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2023-07-24 14:37:09 | RESTAURANT REMODEL | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) EGRESS GATES CANNOT BE MORE THAN 4 FEET WIDE PER = | | FBC 1010.2 GATES. GATES SERVING THE MEANS OF EGRESS | | SYSTEM SHALL COMPLY WITH THE REQUIREMENTS OF THIS | | SECTION. GATES USED AS A COMPONENT IN A MEANS OF EGRESS | | SHALL CONFORM TO THE APPLICABLE REQUIREMENTS FOR DOORS. | | FBC 1010.1.1SIZE OF DOORS. THE MAXIMUM WIDTH OF A | | SWINGING DOOR LEAF SHALL BE 48 INCHES (1219 MM) | | NOMINAL. THE MINIMUM CLEAR HEIGHT OF DOOR OPENINGS | | SHALL BE NOT LESS THAN 80 INCHES | | | | 2) DRAWING A2.0 SHOWS A FLOOR ELEVATION OF (1'6") | | SHOULD THAT HAVE BEEN REMOVED WHEN THE FLOOR IS NOT | | BEING RAISED? | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|