Plan Review Notes
Plan Review Notes For Permit 23051620
Permit Number 23051620
Review Stop B
Sequence Number 1
Notes
Date Text
2023-06-16 08:46:301ST ROOFING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE: ROOF CLADDING DESIGN PRESSURE FOR FLAT ROOF
 <15' MRH, EXPOSURE C IS -108.0 PSF. (CORRECTED-CT) (SEE
 FBC TABLES R301.2(2) AND R301.2(3). ALSO SEE ROOF
 CLADDING PRESSURES ON PAGE 4 OF 25 OF PRODUCT APPROVAL
 FL16709-R10.)
 MAX DESIGN PRESSURE FOR SYSTEM W-5 IS -60.0 PSF.
  
 1.PROVIDE A FL PRODUCT APPROVAL OR MIAMI-DADE NOA FOR
 THE PROPOSED ROOFING THAT MEETS OR EXCEEDS THE DESIGN
 PRESSURE OF -180.0 PSF.
 FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS,
 EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS.
 NOTE: NOAS DO NOT HAVE COVER SHEETS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  