Plan Review Notes For Permit 23051620 |
Permit Number |
23051620 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2023-06-16 08:46:30 | 1ST ROOFING REVIEW | | RESULTS: CORRECTIONS NEEDED | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | PLANS EXAMINER II | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NFPA 70 2017 EDITION NEC 2017 | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | NOTICE: ROOF CLADDING DESIGN PRESSURE FOR FLAT ROOF | | <15' MRH, EXPOSURE C IS -108.0 PSF. (CORRECTED-CT) (SEE | | FBC TABLES R301.2(2) AND R301.2(3). ALSO SEE ROOF | | CLADDING PRESSURES ON PAGE 4 OF 25 OF PRODUCT APPROVAL | | FL16709-R10.) | | MAX DESIGN PRESSURE FOR SYSTEM W-5 IS -60.0 PSF. | | | | 1.PROVIDE A FL PRODUCT APPROVAL OR MIAMI-DADE NOA FOR | | THE PROPOSED ROOFING THAT MEETS OR EXCEEDS THE DESIGN | | PRESSURE OF -180.0 PSF. | | FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS, | | EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS. | | NOTE: NOAS DO NOT HAVE COVER SHEETS. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|