Plan Review Notes
Plan Review Notes For Permit 23051306
Permit Number 23051306
Review Stop B
Sequence Number 1
Notes
Date Text
2023-06-06 09:24:00JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC B 107.2.1 SUBMITTED TABLE 1A GABLE ROOF-ASCE
 7-16 (3:12 AND OVER) PAGE #23 OF THE FLORIDA HIGH WIND
 CONCRETE AND CLAY TILE INSTALLATION MANUEL 6TH EDITION
 IS NOT APPROPRIATE FOR THIS PROJECT. SUBMITTED ROOF
 DIAGRAM SHOWS A HIP ROOF. SUBMIT THE CORRECT TABLES;
 TABLE 1A HIP ROOF-ASCE 7-16 (3:12 AND OVER) PAGE #24 &
 TABLE 2 HC HIP ROOF-ASCE 7-16 EXPOSURE C- PAGE #26 WITH
 ALL APPLICABLE CATEGORIES HIGHLIGHTED/CIRCLED. PLEASE
 NOTE: EXPOSURE CATEGORY IS C; WIND SPEED 170 MPH.
 2. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF
 DIAGRAM/SKETCH TO INDICATE THE AREAS TO RECEIVE NEW
 ROOFING CLEARLY IDENTIFIED ON DRAWING AND INCLUDE ROOF
 SLOPE(S), MEAN ROOF HEIGHT(S).
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved