Date |
Text |
2023-06-21 10:29:11 | JONATHAN BROOKS JR. |
| BUILDING PLANS EXAMINER |
| WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM |
| PHONE (561) 805-6656 |
| EMAIL: [email protected] |
| |
| 1ST REVIEW: FBC 2020 7TH EDITION |
| FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| FBC B = FBC BUILDING |
| FBC R = FBC RESIDENTIAL |
| FBC EB = FBC EXISTING BUILDING |
| FBC A = FBC ACCESSIBILITY |
| FBC EC = FBC ENERGY CONSERVATION |
| WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT |
| CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. |
| |
| 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL5259-R39 |
| WAS NOT APPROVED ON THE 8TH OF JUNE 2023; IT WAS |
| APPROVED ON THE 20TH OF JUNE 2023. PLEASE PROVIDE THE |
| APPROVED VERSION TO INCLUDE COVER PAGE(S); IT COVERS |
| MULTIPLE PRODUCT TYPES; ROOF COVER OPTIONS; ALLOWABLE |
| UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS, ALLOWABLE |
| SUBSTRATES & ATTACHMENT LIMITATIONS. SELECT OPTIONS |
| FROM EACH CATEGORY TO BE USED; SELECT FROM TABLE 4A |
| DIRECT-TO-DECK UNDERLAYMENT IN TILE ROOF APPLICATIONS |
| OR TABLE 4B 2-PLY UNDERLAYMENT SYSTEMS IN TILE ROOF |
| APPLICATIONS. ALL APPLICABLE DETAILS AND ATTACHMENTS |
| MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL |
| DRAWINGS. |
| 2. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020 |
| CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED |
| HIP & RIDGE TILE ADHESIVE TO BE USED. SUBMITTED PRODUCT |
| APPROVAL FL6267-R17 IS NOT A HIP & RIDGE TILE ADHESIVE. |
| SECOND REQUEST. |
| 3. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A ROOF |
| DIAGRAM/SKETCH WITH THE AREAS TO RECEIVE NEW ROOFING |
| CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF SLOPE(S), |
| MEAN ROOF HEIGHT(S). FLAT/LOW SLOPE ROOFS MUST SHOW |
| POSITIVE DRAINAGE. SECOND REQUEST. |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| |