Plan Review Notes
Plan Review Notes For Permit 23051022
Permit Number 23051022
Review Stop B
Sequence Number 6
Notes
Date Text
2023-07-26 09:41:04RESIDENTIAL (R3)RE-ROOF SIXTH BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #23051022
 333 MURRAY RD
  
 PREVIOUS COMMENT FOR FLAT ROOF:
 2- NEW FLAT ROOF NOA 22-0706.08 WAS SUBMITTED. NEED TO
 CLEARLY MARK/IDENTIFY WHICH ASSEMBLY IS GOING TO BE
 INSTALLED. IF SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED. SEE GENERAL
 LIMITATION #7 ON LAST PAGE OF NOA SUBMITTED.
  
 RESPONSE:
 NEW FLORIDA PRODUCT APPROVAL FL16717-R13 SUBMITTED. THE
 DESIGN PRESSURES OF -112.5 PSF OF SELECTED ASSEMBLY
 W107 DON'T MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES
 #3 FOR THIS TWO STORY BUILDING AS REQUIRED BY
 SEC.R301.2.1 FBC-RESIDENTIAL. NEED TO PROVIDE SIGNED
 AND SEALED RAS 117 CALCULATIONS AS REQUIRED BY
 LIMITATION #5.7.2 OF PRODUCT APPROVAL SUBMITTED.
  
  
 PREVIOUS COMMENT:
 4- NEW ROOFING UNDERLAYMENT FLORIDA PRODUCT APPROVAL
 FL5259-R39 SUBMITTED DOESN'T IDENTIFY WHICH APPROVED
 ASSEMBLY IS GOING TO BE INSTALLED. CLEARLY MARK WHICH
 APPROVED ASSEMBLY FROM SECTION 6.1 OF PRODUCT APPROVAL
 SUBMITTED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 RESPONSE:
 UNDERLAYMENT SELECTED IS POLYSTICK TU MAX AND SELECTED
 APPROVED ASSEMBLY 6.3.12 ON PAGE 9 OF 9 IS FOR CONCRETE
 DECKS. THIS HOUSE DOESN'T HAVE A CONCRETE DECK. NEED TO
 SELECT ASSEMBLY FOR DECK TYPE THAT MATCHES THIS HOUSE.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  