Date |
Text |
2023-06-27 13:37:03 | WEST PALM BEACH DEVELOPMENT SERVICES |
| BUILDING DIVISION |
| 2020 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 23050920 |
| ADD: 3501 VILLAGE BLVD # 203 |
| CONT: MELTINI KITCHEN AND BATH |
| TEL: 561-742-9903 |
| E-MAIL: [email protected] |
| |
| 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE, BUILDING. |
| |
| 2ND REVIEW |
| DATE: TUES. JUNE 27TH/23 |
| ACTION: DENIED |
| |
| 1) 2ND REQUEST. MASTER BATH & GUEST BATH STRUCTURAL |
| SHEET WRITTEN IN PENCIL 24X24 FLOOR TILE. THIS |
| STATEMENT IS NOT ON THE KITCHEN FLOOR PLAN. SUBMITTED |
| FOR 2ND REVIEW A SPEC SHEET FOR SAM 3, A SPEC SHEET |
| FROM PATRIOT FLOORING SUPPLIES FOR SUPER SAM 125 A |
| THIRD PRODUCT PROFLEX SUPER SIM 90 TEST STC 52 WHICH |
| PRODUCT ARE YOU TRYING TO USE OF THE 3 PRODUCTS. SAM 3 |
| & SAM 125 ARE NOT TESTING REPORTS. THE CITY OF WPB DOES |
| HAVE ALL 3 REQUIRED TESTING REPORTS IF YOU ARE USING |
| THE PROFLEX SUPER SIM90 PRODUCT AND ALL 3 TEST PASS. |
| |
| FLOOR INSULATION/ UNDERLAYMENT (FBC-B 2020) FOR TILE, |
| STONE, MARBLE, VINYL (LYT/ LYP), LAMINATE FLOORING AND |
| WOOD FLOORING ALL NEED TO HAVE HAD THE SOUND |
| UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO THE FOLLOWING |
| STANDARDS AND MEET THE QUALIFICATIONS LISTED UNDER EACH |
| OF THE STANDARDS FOR A 6-INCH CONCRETE FLOOR ASSEMBLY/ |
| NO DROPPED CEILING: |
| PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR |
| TYPE II BUILDINGS SHOWING COMPLIANCE WITH: |
| |
| 1A)2ND REQUEST. FBC-B 2020 1207.3 STRUCTURE-BORNE |
| SOUND. FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS |
| OR BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA |
| WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION |
| CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD |
| TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492. |
| |
| 1B) PROFLEX SUPER SIM 90 MAKES THE STC= 52DB. |
| FBC-B 2020 1207.2 AIR-BORNE SOUND. WALLS, PARTITIONS |
| AND FLOOR/CEILING ASSEMBLIES SEPARATING DWELLING UNITS |
| FROM EACH OTHER OR FROM PUBLIC OR SERVICE AREAS SHALL |
| HAVE A SOUND TRANSMISSION CLASS (STC) OF NOT LESS THAN |
| 50 (45 IF FIELD TESTED) FOR AIR-BORNE NOISE WHEN TESTED |
| IN ACCORDANCE WITH ASTM E 90. |
| |
| 1C) 2ND REQUEST. FLAME SPREAD- FBC-B 2020 603.1. |
| EXCEPTION 2. (TILE & MARBLE) INSULATION INSTALLED |
| BETWEEN A FINISHED FLOOR AND SOLID DECKING WITHOUT |
| INTERVENING AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME |
| SPREAD INDEX OF NOT MORE THAN 200. |
| FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS |
| A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL |
| MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A |
| MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. |
| |
| 2) A TRANSMITTAL LETTER / NARRATIVE LISTING THE |
| ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF |
| THE REVISION MADE, IDENTIFYING THE SHEET OR |
| SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| ANTICIPATED COOPERATION. |
| |
| PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS |
| REVIEW, SUBSEQUENT |
| REMARKS MAYBE MADE IN THE NEXT REVIEW CYCLE. |
| |
| MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM |
| PART-TIME/ SEMI-RETIRED. |
| |
| IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET |
| BACK INTO THE OFFICE CALL |
| (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. |
| THANK YOU. |
| |
| JAMES A. WITMER BN, PX, SFP, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| DEPARTMENT |
| 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6717 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |