2023-05-24 18:16:40RESIDENTIAL BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #23050709
 526 51ST ST
  
 NOTE:
 LEVEL 1 ALTERATION. SEC. 602 FBC-EXISTING BUILDING.
 SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK SHALL
 COMPLY WITH THE MATERIALS AND METHODS REQUIREMENTS IN
 THE FLORIDA BUILDING CODE.
  
 1- SHINGLES ROOFING UNDERLAYMENT:
 GARDNER UNDERLAYMENT NOA 22-1221.05 SUBMITTED. NEED TO
 CLEARLY SPECIFY WHICH UNDERLAYMENT IS GOING TO BE USED
 TO COMPLY WITH SHINGLES ROOFING UNDERLAYMENT SEC.
 R905.1.1.1 FBC-RESIDENTIAL.
 NOTE: IF USING APOC TUFF-FELT 26, THEN NEED TO SPECIFY
 TWO LAYERS AS REQUIRED BY OPTION #4 OF SEC. R905.1.1.1
 FBC-RESIDENTIAL. PLEASE SPECIFY ON PRODUCT APPROVAL
 SUBMITTED.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  