Plan Review Notes For Permit 23050467 |
Permit Number |
23050467 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2023-05-30 09:03:23 | BUILD OUT | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) DRAWING S-1 - UNDER "OCCUPANCY CLASSIFICATION" NOTE | | - SHOWS 2010 FBC - SHOULD BE 2020 FBC | | | | 2) BUILDING CONSTRUCTION TYPE IS SHOWN AS V - PLEASE | | SHOW VA OR VB FBC CHAPTER 6 | | | | 3) PLEASE SHOW THE ACCESSIBLE BAR AREA - SHOW BAR TOP | | HEIGHT, CLEAR FLOOR SPACE, KNEE AND TOE CLEARANCE ETC. | | - FBC A 226.2 AND 902 | | | | 4) PLEASE SHOW THE DOOR MANUVERING SPACE TO EXIT THE | | RESTROOMS ( 18 INCH CLEARANCE FROM THE DOOR TO THE | | SINK) - FBC A 404 | | | | 5) PLEASE SHOW THE ACCESSIBLE SALES COUNTER HEIGHT AND | | CLEAR FLOOR SPACE IN UNIT "B" - FBC 904.4 | | | | 6) DRAWING S-1 SAYS FIRE SPRINKLERS - DRAWING LS - 1 | | SAYS NO FIRE SPRINKLERS - UNDER OCCUPANCY NOTES - | | PLEASE CLARIFY | | | | | | |
|