Plan Review Notes
Plan Review Notes For Permit 23040440
Permit Number 23040440
Review Stop B
Sequence Number 1
Notes
Date Text
2023-04-14 16:20:46 
 BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT:
  
 REVIEWED: 23040440
  
 FLORIDA BUILDING CODE,7TH EDITION (2020)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC BUILDING
 FBC EXISTING BUILDING
  
 AS PER SECTION 107.2.1
  
 COMMENTS: BUILDING FAILED
  
  
  
 1. PROVIDE WALL SECTION AT TUB AND SHOWERS OR NOTE THAT
 YOU WILL COMPLY WITH REINFORCEMENT FOR THE FHA
 MENDATORY BATHROOM.
  
 2. [FBC 603.1]ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
 SEE 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM
 E 84 OR UL 723.:
  
 PROVIDE ASTM E-84 FLAME SPREAD TEST FOR WHISPER MAT.
  
  
  
  
  
 IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT
 HESITATE TO CONTACT ME
  
 LOUIS BOND, AIA
 BUILDING PLANS EXAMINER II
 DEVELOPMENT SERVICES DEPT.
 BUILDING DIVISION
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 PH: 561-805-6729
 FX: 561-805-6676
 EMAIL: [email protected]
  
  
 NOTES:
 PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  
  
  