Plan Review Notes
Plan Review Notes For Permit 23031862
Permit Number 23031862
Review Stop B
Sequence Number 3
Notes
Date Text
2023-04-18 08:53:38PLAN
 REVIEW COMMENTS
  
 3RD REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 1) ON PAGE 1 OF THE ROOFING PRODUCT APPROVAL THAT WAS
 SUBMITTED THE SYSTEMS THAT ARE SPECIFIED AT THE TOP OF
 THE PAGE ARE W-30 AND C-20. THE W-30 SYSTEM IS FOR WOOD
 ROOF DECKS AND THE C-30 IS FOR CONCRETE ROOF DECKS. THE
 DESIGN PRESSURE FOR THE W-30 WOOD DECK ON PAGE 10 HAS A
 MAXIMUM DESIGN PRESSURE OF -60 PSF. THIS DESIGN
 PRESSURE WILL NOT WORK FOR THE PERIMETER AND ROOF
 AREAS. YOU WILL HAVE TO SUBMIT DIGITALLY SIGNED
 ENHANCED FASTENING CALCULATIONS IF YOU WANT TO USE THAT
 SYSTEM. FBC-R301.2.1
  
 2) PLEASE SPECIFY ON THE ROOF DRAWING WHICH PART OF THE
 ROOF IS WOOD AND WHICH PART IS CONCRETE. FBC 107.2.1
  
 3) THE VALUATION ON THE PERMIT APPLICATION OF $7200.00
 APPEARS TO BE TOO LOW. SUBMIT AN ITEMIZED COST
 BREAKDOWN FOR THIS ROOFING PROJECT INCLUDING ALL COSTS
 FOR MATERIALS, LABOR, COSTS AND OVERHEAD. BUILDING
 PERMIT VALUATION. FOR PERMITTING PURPOSES, VALUATION OF
 FBC 109.3 BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRIC,
 PLUMBING, MECHANICAL, INTERIOR FINISH, RELATIVE SITE
 WORK, ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS,
 OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  
 4) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH
 OF THE REVIEW COMMENTS HAS BEEN ADDRESSED.
  
  
  