2023-04-05 13:50:26RESIDENTIAL (R3) BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 REVISION# 23031810
 201 SUMMA ST
  
 1-PROVIDE PRODUCT APPROVAL FOR:
  
 (A)ROOF TILE HIP & RIDGE METAL SUPPORT.
 RESPONSE:
 ARCHITECT'S RESPONSE LETTER STATES " EAST COAST METALS
 RIDGE ADDED TO PRODUCT APPROVAL INDEX: FL5374-R6".
 PRODUCT APPROVAL WAS NOT SUBMITTED. NEED TO SUBMIT.
  
 (B)STRUCTURAL MULLIONS THAT MEETS DESIGN PRESSURES FOR
 WINDOW "J".
 RESPONSE:
 ARCHITECT'S RESPONSE LETTER STATES " MULLION
 HIGHLIGHTED PAGE 12 OF MULLION NOA".
 PAGE 9 OF 25 OF MULLION NOA SPECIFIES 1"X3.125"X.5"
 ALUMINUM TUBE MULLION.
 THIS MULLION SIZE DOESN'T MEET THE DESIGN PRESSURES
 CALCULATED BY THE ARCHITECT OF RECORD. REVISE MULLION
 SIZE AS REQUIRED.
  
 (C)EXTERIOR OUTSWING DOOR ON NEW UNDER STAIR STORAGE.
 RESPONSE:
 ARCHITECT'S RESPONSE LETTER STATES "REFER TO PRODUCT
 INDEX NOA 20-0406.03".
 THIS NOA 20-0406.03 IS FOR MULLIONS. REVISE AS REQUIRED
 AND PROVIDE PRODUCT APPROVAL.
  
 (D)EXTERIOR SOLID OUTSWING DOOR ON NEW PRIVACY WALL
 NEXT TO THE NEW STAIRWAY.
 RESPONSE:
 ARCHITECT'S RESPONSE LETTER STATES "THIS IS A GARDEN
 GATE. WILL BE ENGINEERED- SHOP DRAWING TO BE
 SUBMITTED."
 NOTE: OK. SUBMIT ENGINEERING REVIEWED BY ARCHITECT
 PRIOR TO INSTALLATION.
  
 (E)ENTRY DOOR WITH SIDELITES AS SHOWN ON PLANS.
 RESPONSE:
 ARCHITECT'S RESPONSE LETTER STATES "SEE PRODUCT INDEX."
 PRODUCT APPROVAL LISTED IN THE INDEX WAS NOT SUBMITTED.
 NEED TO SUBMIT.
  
 2-DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT
 APPROVALS.
  
 3- REVISED ENERGY CALCULATIONS HAVE A COPY OF THE
 ENGINEER'S DIGITAL SIGNATURE. NEED ORIGINAL
 SEAL/SIGNATURE WHEN SUBMITTED FOR PUBLIC RECORDS.
 ELECTRONIC SUBMITTALS NEED VERIFIABLE DIGITAL
 SIGNATURE.
  
 ENGINEERS
 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND
 SEALING ELECTRONICALLY TRANSMITTED PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
  
 NEW COMMENTS BASED ON REVISED ROOF PRODUCT APPROVALS
  
 3- WINDSOR ROOF TILE NOA LISTED ON PRODUCT APPROVAL
 INDEX(21-0201.05) AND NOA SUBMITTED(22-0201.05)DON'T
 MATCH. REVISE AS REQUIRED TO MATCH. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 4- NEW ROOF TILE NOA SUBMITTED: CLEARLY IDENTIFY
 ADHESIVE PADDY SIZE TO BE USED AS REQUIRED BY CITY
 POLICY FOR ALL ROOFING PERMITS TO VERIFY COMPLIANCE
 WITH THE REQUIRED UPLIFT MOMENT FOR TILE. SEC R301.2.1
 FBC-RESIDENTIAL.
 NOTE: COORDINATE WITH FOAM ADHESIVE COMMENT BELOW.
  
 5- ROOF TILE ADHESIVE NOA SUBMITTED: CLEARLY IDENTIFY
 ADHESIVE PADDY SIZE TO BE USED AS REQUIRED BY CITY
 POLICY FOR ALL ROOFING PERMITS TO VERIFY THE REQUIRED
 UPLIFT MOMENT FOR TILE. SEC R301.2.1 FBC-RESIDENTIAL.
 NOTE: COORDINATE WITH ROOF TILE COMMENT ABOVE.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
  