Plan Review Notes For Permit 23031258 |
Permit Number |
23031258 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2023-04-19 10:18:13 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL5259-R37 | | HAS BEEN REVISED TO FL5259-R38. PLEASE PROVIDE A | | COMPLETE SET TO INCLUDE COVER PAGE(S); IT COVERS | | MULTIPLE PRODUCT TYPES; ROOF COVER OPTIONS; ALLOWABLE | | UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS, ALLOWABLE | | SUBSTRATES & ATTACHMENT LIMITATIONS. SELECT OPTIONS | | FROM EACH CATEGORY TO BE USED; SELECT FROM TABLE 4A | | DIRECT-TO-DECK UNDERLAYMENT IN TILE ROOF APPLICATIONS | | OR TABLE 4B 2-PLY UNDERLAYMENT SYSTEMS IN TILE ROOF | | APPLICATIONS. ALL APPLICABLE DETAILS AND ATTACHMENTS | | MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL | | DRAWINGS. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|