Plan Review Notes For Permit 23030381 |
Permit Number |
23030381 |
|
Review Stop |
B |
Sequence Number |
3 |
|
Notes |
Date |
Text |
2023-07-07 11:59:47 | NEW COMMERCIAL BUILDING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) THE BUILDING PLACEMENT ON THE SITE SHOWN ON DRAWING | | T-100 & A.100 DO NOT MATCH - 8TH STREET IS SHOWN ON THE | | SOUTH SIDE OF DRAWING T-100 AND ON THE NORTH SIDE OF | | A-100 - PLEASE CLARIFY. | | | | 2) SINCE 8TH STREET IS NOT SHOWN ON THE SOUTH SIDE ON | | DRAWING A-100 - PLEASE SHOW THE SOUTH EXTERIOR WALL | | WHICH IS 5"5" FROM THE PROPERTY LINES TO BE 1 HOUR FIRE | | RATED FBC TABLE 602 | | | | 3) PLEASE SHOW THE SOUTH EXTERIOR WALL OPENING | | CALCULATIONS BASED ON FBC TABLE 705.8 | | | | | | | | |
|