2023-06-23 16:42:52 | 2ND REVIEW FBC-2020 RES. GAS |
| PERMIT- 23021087 |
| 6/23/23 |
| |
| CODES IN EFFECT: |
| FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION |
| 2020 |
| FS- FLORIDA STATUTES |
| FAC- FLORIDA ADMINISTRATIVE CODE |
| WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| |
| PLAN REVIEW RESULTS: DENIED. 2ND REQUEST FOR GAS PLANS. |
| THE GAS CONTRACTOR HAS SUBMITTED A GAS SUB-PERMIT |
| APPLICATION (23040242) WHICH REQUIRES PLANS TO BE |
| SUBMITTED UNDER THIS MASTER PERMIT. PLEASE SUBMIT THE |
| DRAWINGS PER THE COMMENTS BELOW. |
| |
| 1) SHEET A2: THE PLAN SHOWS A NEW GAS FIRED TANKLESS |
| WATER HEATER MOUNTED ON THE REAR WALL OF THE HOUSE. |
| PLEASE PROVIDE A GAS PIPING RISER DIAGRAM PER SEC. |
| 107.3.5.3 WPB. THE RISER SHALL INCLUDE ALL NEW AND |
| EXISTING PIPING AT THE RESIDENCE IN COMPLIANCE WITH |
| SECS. G2412.3 & G2412.4 FBC RES. REFER TO FBC RES. |
| CHAPTER 24 FUEL GAS. THE RISER SHALL INDICATE: |
| |
| A) TYPE OF GAS- NATURAL OR LP. |
| B) DELIVERY PRESSURE AT THE METER. |
| C) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS. |
| D) TYPES AND SIZES OF PIPING. |
| E) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER |
| TO THE MOST REMOTE APPLIANCE OUTLET. |
| F) BRANCH AND CUT PIPE LENGTH MEASUREMENTS. |
| G) LOCATIONS OF REGULATORS, SHUTOFF VALVES. |
| H) OUTLET PRESSURES AT REGULATORS. |
| I) LOCATIONS AND TYPES OF PIPE SLEEVES. |
| K) PIPE SIZING TABLES. |
| . |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. |
| CHRISTOPHER L. COLE |
| MECHANICAL/PLUMBING PLANS EXAMINER |
| 401 CLEMATIS STREET |
| WEST PALM BEACH FL 33401 |
| 561-805-6719 |
| [email protected] |
| |