Date |
Text |
2023-05-22 15:42:32 | RE-ROOF BUILDING REVIEW COMMENTS |
| CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| PERMIT #23020784 |
| 1500 FLORIDA AVE |
| |
| 1- FLAT ROOF NOA 21-1229.01 SUBMITTED: |
| A)SELECTED ASSEMBLY SYSTEM TYPE C(1) ON PAGE 7 OF 28 |
| CAN NOT BE USED. THIS ASSEMBLY IS LIMITED BY GENERAL |
| LIMITATION #9. THIS LIMITATION DOESN'T ALLOW NEITHER |
| RATIONAL ANALYSIS, NOT EXTRAPOLATION FOR ENHANCED |
| FASTENING. SEE GENERAL LIMITATION #9 ON LAST PAGE OF |
| NOA. NEED TO SELECT ANOTHER ASSEMBLY WITH GENERAL |
| LIMITATION #7 THAT ALLOW NAIL ENHANCEMENT CALCULATIONS. |
| SEC. 107.2.1 CITY AMENDMENTS. SEC. R301.2.1 |
| FBC-RESIDENTIAL. |
| |
| B)NAIL ENHANCEMENT CALCULATIONS SUBMITTED ARE FOR |
| ANOTHER NOA AND FOR ANOTHER ADDRESS 213 N WARE DR. |
| COORDINATE WITH ITEM 1(A) AND RESUBMIT. |
| SEC. 107.2.1 CITY AMENDMENTS. |
| |
| C) ROOF ZONES SPECIFIED ON THE CALCULATIONS SUBMITTED |
| ARE INCORRECT. ARCHITECT NEEDS TO USE THE REVISED ZONES |
| AND PROVIDE THE ZONES DIMENSIONS AS REQUIRED BY FIGURE |
| R301.2(7) FBC-RESIDENTIAL OF CURRENT 2020 CODE. |
| SEC. 107.2.1.2 CITY AMENDMENTS. |
| |
| PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| QUESTIONS REGARDING THESE COMMENTS, |
| JULIO GOMEZ |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| DEVELOPMENT SERVICES DEPARTMENT |
| BUILDING DIVISION |
| (561)805-6712 |
| [email protected] |
| |