Plan Review Notes For Permit 23020770 |
Permit Number |
23020770 |
|
Review Stop |
G |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2023-03-10 09:03:50 | 1ST REVIEW FBC-2020 RES. FUEL GAS | | PERMIT- 23020770 | | 3/10/23 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE GAS RISER IS INCOMPLETE BECAUSE IT DOESN???T | | INCLUDE THE EXISTING PIPING AND APPLIANCES AT THE | | RESIDENCE. A COMPLETE GAS RISER IS REQUIRED PER SECS. | | G2412.3 & G2412.4 FBC RES. BASED ON RECENT PERMIT | | 22121418 THERE IS AN EXISTING GAS RANGE, HOWEVER IT IS | | NOT CLEAR IF THERE ARE OTHER EXISTING GAS-FIRED | | APPLIANCES. PLEASE REVISE THE DRAWING ACCORDINGLY. | | | | 2) SHOW THE NEW TANKLESS WATER HEATER EXHAUST | | CLEARANCES TO AIR INTAKES AND OPERABLE OPENINGS INTO | | THE BUILDING- SEC. G2427.8 & G2448.1 FBC RES. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|