Plan Review Notes For Permit 23020290 |
Permit Number |
23020290 |
|
Review Stop |
G |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2023-02-13 16:24:38 | 1ST REVIEW FBC-2020 FUEL GAS | | PERMIT- 23020290 | | 2/13/23 | | | | CODES IN EFFECT: | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET P2.1: INDICATE THE MEANS OF PROVIDING | | COMBUSTION AIR FOR THE GAS-FIRED COOKING APPLIANCES- | | SEC. 304.1 FBC FG. PLEASE INCLUDE CALCULATIONS. | | | | 2) P2.1 & P2.2: PROVIDE A GAS WATER HEATER DIRECT VENT | | EXHAUST AND INTAKE DIAGRAM SHOWING THE TYPES AND SIZES | | OF THE VENT AND DUCT, THE VENT AND DUCT RUN LENGTHS, | | AND TERMINATION LOCATIONS- SECS. 503.2.3, 503.8, AND | | 624.1 FBC FG. | | | | 3) THE ENERGY EFFICIENCY REPORT DOES NOT PROVIDE | | COMPLIANCE DATA FOR THE WATER HEATERS- TABLE C404.2 FBC | | EC. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|