2023-05-31 17:04:11 | PETER E VALENTI |
| BUILDING PLANS EXAMINER II/INSPECTOR |
| [email protected] |
| 561 805 6673 |
| |
| FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| FBC B = FBC BUILDING |
| FBC R = FBC RESIDENTIAL |
| FBC EB = FBC EXISTING BUILDING |
| FBC A = FBC ACCESSIBILITY |
| FBC EC = FBC ENERGY CONSERVATION |
| FBC M = FBC MECHANICAL |
| FBC FG = FBC FUEL GAS |
| |
| BUILDING REVIEW APPROVED WITH PROVISOS: |
| |
| FBC B 1609.1.2, FBC B 1609..4.4.1 & FAC RULES: FL 61G |
| 20, FL 61G1-23.015, FL 61G15-30, THE FOLLOWING ITEMS |
| SHALL BE CONSIDERED DEFERRED SUBMITTALS: EXTERIOR |
| DOORS, WINDOWS, MULLIONS, ROOF HATCHES, PANEL WALLS, |
| STORE FRONTS, CURTAIN WALLS, WALL LOUVERS, EFIS |
| SYSTEMS, ROOFING PRODUCTS AND ASSEMBLIES, LIGHTWEIGHT |
| CONCRETE INSULATION, ROOF TOP VENTILATORS, |
| PRE-ENGINEERED A/C STANDS. IF THERE ARE ANY SHOP |
| DRAWINGS INVOLVED, THE DELEGATED ENGINEER SHALL FORWARD |
| THE THE DELEGATED DOCUMENT TO THE ENGINEER OF RECORD |
| FOR REVIEW AND SHALL PROVIDE A REVIEW STAMP ON |
| DOCUMENTS. THE ARCHITECT IS RESPONSIBLE FOR SUPERVISING |
| AND REVIEWING ALL PROJECT DATA, REPORTS, AND SHOP |
| DRAWINGS. |
| |
| FBC B 107.2.1, SHEET S.002 HAS HEADING DEALING |
| WITH WELDING & STRUCTURAL STEEL FOR THE PROJECT. WELDED |
| OR BOLTED CONNECTIONS. THIS BUILDING CONTAINS EITHER |
| BOLTED AND OR WELDED CONNECTIONS. THE CONTRACTOR IS |
| REQUIRED TO PROVIDE WELD PROCEDURE SPECIFICATIONS & |
| WELDER OPERATOR PERFORMANCE QUALIFICATION RECORDS IN |
| ACCORDANCE WITH THE REFERENCED STANDARDS AT TIME OF |
| INSPECTION FOR FIELD WIELDING, ON THE JOB???SITE |
| WIELDING. THIRD PARTY CERTIFICATION WILL BE REQUIRED. |
| THE OWNER MAY JUST HIRE A 3RD PARTY ENGINEERING FIRM TO |
| COMPLETE AND APPROVE THE FORMER INSPECTIONS. REPORTS |
| SUBMITTED TO BUILDING INSPECTOR AT TIME OF FRAMING |
| INSPECTION. |
| 2020 FBC???B 2204.1 WELDING |
| 1. WELD PROCEDURES SPECIFICATIONS |
| 2. QUALIFICATIONS OF WELDING PERSONAL |
| 2017 FBC???B 2204.2 BOLTING. |
| |
| |
| |
| |